250 HP 1430 rpm slip ring motor

Short answer

Main dimensions: D=39.6 cm, L=37.3 cm. Stator turns per phase Ts=32, 48 slots with 4 conductors per slot. Conductor area is 54.8 mm², slot area about 548 mm².

Determine the main dimensions, turns per phase, number of slots, conductor size and slot area of a 250 HP, 3-φ, 400 V, 50 Hz, 1430 rpm slip ring induction motor. Assume Bav = 0.5 Wb/m², ac = 30000 ampere conductors per meter, efficiency = 0.9, Power factor = 0.9, Current density = 3.5 A/mm². The slot space factor is 0.4 and ratio of core length to pole pitch is 1.2. The machine is delta connected. Appropriate values for additional data required may be assumed.

Data: 250 HP =250×746=186.5= 250 \times 746 = 186.5 kW; 400 V, 50 Hz, 1430 rpm, so 4 poles with Ns=1500N_s = 1500 rpm (ns=25n_s = 25 rps); delta (Eph=400E_{ph} = 400 V); η=0.9\eta = 0.9, pf =0.9= 0.9, Bav=0.5B_{av} = 0.5 Wb/m²; δ=3.5\delta = 3.5 A/mm²; L/τ=1.2L/\tau = 1.2; space factor 0.4. Given ac=30000ac = 30000 A/m. Assumed: Kw=0.955K_w = 0.955 (full-pitch, 60° spread), 1 HP = 746 W.

Main dimensions

Q=186.50.9×0.9=230.25 kVAC0=11Bav ac Kw×10−3=11×0.5×30000×0.955×10−3=157.58D2L=QC0ns=230.25157.58×25=0.05845 m3\begin{aligned} Q &= \frac{186.5}{0.9 \times 0.9} = 230.25\ \text{kVA} \\ C_0 &= 11B_{av}\,ac\,K_w\times10^{-3} = 11 \times 0.5 \times 30000 \times 0.955 \times 10^{-3} = 157.58 \\ D^2L &= \frac{Q}{C_0n_s} = \frac{230.25}{157.58 \times 25} = 0.05845\ \text{m}^3 \end{aligned}

With L=1.2τ=1.2πD/4=0.9425DL = 1.2\tau = 1.2\pi D/4 = 0.9425D:

D3=0.058450.9425=0.0620⇒D=0.396 m,L=0.373 mD^3 = \frac{0.05845}{0.9425} = 0.0620 \Rightarrow D = 0.396\ \text{m}, \quad L = 0.373\ \text{m}

Turns per phase

τ=π×0.396/4=0.311 mΦ=BavτL=0.5×0.311×0.373=0.0580 WbTs=Eph4.44fΦKw=4004.44×50×0.0580×0.955=32.5\begin{aligned} \tau &= \pi \times 0.396/4 = 0.311\ \text{m} \\ \Phi &= B_{av}\tau L = 0.5 \times 0.311 \times 0.373 = 0.0580\ \text{Wb} \\ T_s &= \frac{E_{ph}}{4.44f\Phi K_w} = \frac{400}{4.44 \times 50 \times 0.0580 \times 0.955} = 32.5 \end{aligned}

Number of slots

Choose q=4q = 4: Ss=3×4×4=48S_s = 3 \times 4 \times 4 = 48 slots; slot pitch =π×396/48=25.9= \pi \times 396/48 = 25.9 mm (acceptable for this size). Conductors per slot =6×32.5/48=4.07≈4= 6 \times 32.5/48 = 4.07 \approx 4, so Zs=192Z_s = 192 and Ts=32T_s = 32 (gap density becomes 0.508 Wb/m², acceptable).

Conductor cross-section

Iph=Q×1033Eph=2302473×400=191.9 A,as=191.93.5=54.8 mm2I_{ph} = \frac{Q\times10^3}{3E_{ph}} = \frac{230247}{3 \times 400} = 191.9\ \text{A}, \qquad a_s = \frac{191.9}{3.5} = 54.8\ \text{mm}^2

(A rectangular strip of about 4.5×12.24.5 \times 12.2 mm.)

Slot area

Aslot=4×54.80.4=548 mm2A_{slot} = \frac{4 \times 54.8}{0.4} = 548\ \text{mm}^2

Answer: D=39.6D = 39.6 cm, L=37.3L = 37.3 cm, Ts=32T_s = 32, 48 slots with 4 conductors each, conductor area 54.8 mm², slot area ≈548\approx 548 mm².