Skip to main content

Temperature difference in slot copper strips

Short answer

Heat generation density = 3.36×10⁵ W/m³. (i) Centre‑to‑overhang: θ = (q ρ_th L²)/8 = 26.25 °C. (ii) Total slot loss 40.32 W, heat flow area 0.034 m², insulation resistance 0.353 °C/W, giving temperature difference ≈ 14.2 °C.

A generator has open slots each containing 3 strips of copper in the arrangement of three strips along the depth of the slot. The length of the slot portion of the conductor is 0.5 m, each strip has a cross section of 8×10 mm² and current density in the strip is 4 A/mm². The electrical and thermal resistivities of the copper are 0.021×10⁻⁶ Ω-m and 0.0025 Ω-m respectively. The insulation between the strips and the slot walls is taken as 4 mm thick and has a thermal resistivity of 3 Ω-m. Calculate the temperature difference for the following cases: i) Between the centre of the embedded portion of the strip and the overhang ii) Between the conductor and the slot walls

Assumption: each strip is 8 mm wide (slot width) and 10 mm deep, so the three strips fill a depth of 30 mm. Heat in the slot portion flows (i) along the copper to the cooler overhang, and (ii) across the slot insulation to the iron.

Heat produced per unit volume of copper:

q=J2ρ=(4×106)2×0.021×10−6=3.36×105 W/m3q = J^2\rho = (4\times10^6)^2 \times 0.021\times10^{-6} = 3.36\times10^5\ \text{W/m}^3

i) Centre of embedded portion to overhang

Take xx from the centre of the slot length LL. Heat crossing a section at xx is qAxqAx, and over dxdx the temperature drop is dθ=qAx⋅ρt dx/A=qρtx dxd\theta = qAx \cdot \rho_t\,dx/A = q\rho_t x\,dx. Integrating from 0 to L/2L/2:

θ1=qρt2(L2)2=qρtL28=3.36×105×0.0025×0.528=26.25 ∘C\begin{aligned} \theta_1 &= \frac{q\rho_t}{2}\left(\frac{L}{2}\right)^2 = \frac{q\rho_t L^2}{8}\\ &= \frac{3.36\times10^5 \times 0.0025 \times 0.5^2}{8} = 26.25\ ^\circ\text{C} \end{aligned}

ii) Conductor to slot walls

Loss in the three strips (slot portion):

V=3×(8×10×10−6)×0.5=1.2×10−4 m3P=qV=3.36×105×1.2×10−4=40.32 W\begin{aligned} V &= 3 \times (8\times10\times10^{-6}) \times 0.5 = 1.2\times10^{-4}\ \text{m}^3\\ P &= qV = 3.36\times10^5 \times 1.2\times10^{-4} = 40.32\ \text{W} \end{aligned}

Heat leaves through the two sides and the bottom of the slot (the open top is assumed not to dissipate):

S=(2×30+8)×10−3×0.5=0.034 m2S = (2 \times 30 + 8)\times10^{-3} \times 0.5 = 0.034\ \text{m}^2

Thermal resistance of insulation:

R=ρt tS=3×0.0040.034=0.353 ∘C/WR = \frac{\rho_t\,t}{S} = \frac{3 \times 0.004}{0.034} = 0.353\ ^\circ\text{C/W} θ2=PR=40.32×0.353=14.23 ∘C\theta_2 = PR = 40.32 \times 0.353 = 14.23\ ^\circ\text{C}
   open top (wedge)
  |  [ strip 1 ]  |
  |  [ strip 2 ]  |  <- 4 mm insulation
  |  [ strip 3 ]  |     on sides and bottom
  |_______________|
     slot wall

Answer: (i) ≈ 26.25 °C between the centre of the embedded part and the overhang; (ii) ≈ 14.2 °C between conductors and slot walls.

✓ Answer checked by Claude Sonnet 5.5

All Electric Machine Design chapter 2 questions →