Demand of new municipality 2016, 45,000 pop
Short answer
Design population in 2038 is 62,440. Average daily demand is 8,483 m3/day or 98.2 l/s; fire demand is 562 l/s with about 4,050 m3 reserve; distribution design flow is about 739 l/s.
Data obtained from a baseline survey of a newly formed municipality in year 2016 A.D. are as follows. Population = 45,000, No. of day scholar students in school = 9500, No. of big animals = 8000, No. of small animals = 15000. There are twenty offices, two hospital with total 50 beds. Calculate the water demand of that municipality in design year with base period of 2 years and design period of 20 years. Assume the population growth rate of the community is 1.5% per annum and fire fighting as per National Board of fire under writers.
Survey year 2016; base period 2 years and design period 20 years give the design year 2038, so years after the survey.
Design population
Water demand
Assumed unit rates for a municipality: domestic 110 lpcd; day scholar 5 l/d; big animal 45 l/d; small animal 5 l/d; office staff 45 l/d (10 staff per office); hospital 340 l/bed/d (IS 1172); losses 15%.
| Demand | Quantity | Rate | Demand (l/day) |
|---|---|---|---|
| Domestic (110 lpcd) | 62,440 | 110 l/c/d | 6,868,440 |
| Day scholars | 9,500 | 5 l/c/d | 47,500 |
| Big animals | 8,000 | 45 l/d | 360,000 |
| Small animals | 15,000 | 5 l/d | 75,000 |
| Offices (10 staff each) | 200 | 45 l/staff | 9,000 |
| Hospitals (50 beds) | 50 | 340 l/bed/d | 17,000 |
| Net demand | 7,376,940 |
Losses and wastage of net demand l/day
Fire demand (National Board of Fire Underwriters formula)
thousand.
For a fire lasting 2 hours, the volume is . This volume is kept as fire reserve in the service reservoir; it is not added to the average daily demand, because fire flow is an occasional rate, not a daily consumption.
Design flow with fire
The distribution system is checked for the larger of:
- Maximum day demand + fire flow l/s
- Peak hour demand l/s
So the mains are designed for about 739 l/s.
Answer: Design population = 62,440; average daily demand = 8,483 m/day (98.2 l/s); fire demand = 33,746 l/min (562 l/s), with a 2-hour fire reserve of about 4,050 m in storage; design flow for the distribution system (maximum day + fire) 739 l/s.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Population in survey year from design demand 800 m3 · Water Supply Engineering, chapter 3 · asked 2×
- Demand of rural municipality 2018, 15,000 pop · Water Supply Engineering, chapter 3
- Rural village demand, survey 2070 BS, base year 2073 · Water Supply Engineering, chapter 3
- Demand of rural municipality, base period 3 years · Water Supply Engineering, chapter 3
- Demand of village 2070 BS, base period 5 years · Water Supply Engineering, chapter 3
- Average demand, village survey 2013, design 25 years · Water Supply Engineering, chapter 3 · asked 2×
- Population 2088 by three methods, design year demand · Water Supply Engineering, chapter 3