Storage tank capacity and water level, 20000 L/day

Short answer

Mass curve analysis with continuous inflow of 0.9 m³/h gives a balancing storage of 9 m³. At 10:00 the water depth is 4.3/A m and at 6 PM it is 2.7/A m, where A is the tank cross-sectional area in m².

A rural area has a design year demand of water 20000 liters per day. The demand is met by a continuous system of supply from a river source with measured safe yield of 0.25 lps. The consumption pattern is as follows: estimate the capacity of the storage (balancing) tank. What will be the water level in the tank at a given time (10 / 6 PM) if the cross section area of the tank is "A" ("X")?

Time (Hour)5-77-1212-1717-1919-5
Consumption (%)253520200

Given data

  • Design-year demand = 20,000 L/day = 20 m³/day
  • Safe yield of river = 0.25 lps = 0.25 × 86,400 = 21,600 L/day = 21.6 m³/day, i.e. 0.9 m³/h continuous inflow
  • Consumption: 5–7 h 25%, 7–12 h 35%, 12–17 h 20%, 17–19 h 20%, 19–5 h 0%

Check of source and need of storage

The source yield (21.6 m³/day) exceeds the demand (20 m³/day), so the source is adequate for the day. But the demand rate in 5–7 h is 5/2 = 2.5 m³/h and in 7–12 h it is 1.4 m³/h, both more than the inflow of 0.9 m³/h. A balancing tank is therefore necessary.

Mass-curve table (analytical method)

Inflow: 0.9 m³/h for 24 h. Time is counted from the start of the first demand period; a positive cumulative value means surplus in the tank.

TimeDemand (m³)Inflow (m³)Inflow − demandCumulative
05:00–07:005.001.80-3.20-3.20
07:00–12:007.004.50-2.50-5.70
12:00–17:004.004.50+0.50-5.20
17:00–19:004.001.80-2.20-7.40
19:00–05:000.009.00+9.00+1.60

Total demand = 20.00 m³; total inflow = 21.60 m³.

Capacity

  • Maximum cumulative surplus = 1.60 m³
  • Maximum cumulative deficit = 7.40 m³
  • Balancing capacity = max. surplus + max. deficit = 1.60 + 7.40 = 9.00 m³
  • Because the inflow in a day (21.60 m³) is more than the demand, the extra water simply overflows once the tank is full. The minimum storage that still meets every demand is the largest draw-down, 7.40 m³. The textbook value of 9.00 m³ is on the safe side.

Water level in the tank

With the 9.00 m³ tank, the night inflow (9.00 m³) fills it to the top by 05:00, and any extra overflows. So storage at any time = 9.00 m³ + cumulative value (counted from 05:00). The lowest storage is 9.00 − 7.40 = 1.60 m³, at 19:00.

  • At 10:00: cumulative = −3.20 + (3/5)(−2.50) = −4.70, storage = 9.00 − 4.70 = 4.30 m³
  • At 18:00 (6 PM): cumulative = −5.20 + (1/2)(−2.20) = −6.30, storage = 9.00 − 6.30 = 2.70 m³

For a tank of plan area AA (m²): level at 10:00 =4.30/A= 4.30/A m and level at 6 PM =2.70/A= 2.70/A m. For example, with a 3 m × 3 m tank (A=9A = 9 m²), these are 0.48 m and 0.30 m above the floor. (If only the minimum 7.40 m³ tank were built, it would be full at 05:00 and empty at 19:00, giving 2.70/A2.70/A and 1.10/A1.10/A.)

Answer: Balancing tank capacity ≈ 9 m³ (practical 10 m³). With a 9 m³ tank, the water depth is 4.3/A m at 10:00 and 2.7/A m at 6 PM.