Short answer

Use M16 4.6 bolts in a single row at 40 mm pitch, end distance 30 mm, with 8 mm cover plates on both sides; the joint efficiency is about 61%.

Design a single bolted double cover butt joint to connect boiler plates of thickness 12mm for maximum efficiency. Use M16 bolts of grade 4.6. Boiler plates are of Fe410. Find the efficiency of the joint.

Joint type: single-bolted (one row) double cover butt joint; bolts in double shear. Plates 12 mm, Fe410; M16 bolts grade 4.6, d0=18d_0=18 mm. Covers: two plates of 8 mm (2×8=16≥122\times8=16\ge12 mm).

Strength of one bolt (IS 800:2007 cl. 10.3)

  • Shear (double shear, one plane in thread): Vdsb=4003×1.25(157+201)×10−3=66.14V_{dsb}=\dfrac{400}{\sqrt3\times1.25}(157+201)\times10^{-3}=66.14 kN
  • Bearing on the 12 mm main plate: with a single row there is no pitch in the direction of load, so only the end distance e=30e=30 mm (≥1.5d0=27\ge1.5d_0=27 mm) controls: kb=min⁡(30/54, 0.976, 1)=0.556k_b=\min(30/54,\ 0.976,\ 1)=0.556; Vdpb=2.5kbdtfuγmb=87.5V_{dpb}=\dfrac{2.5k_bdtf_u}{\gamma_{mb}}=87.5 kN
  • Bolt value =66.14=66.14 kN

Pitch for maximum efficiency

Efficiency is highest when the net strength of the plate between bolt holes equals the bolt value, so that no material is wasted:

0.9(p−d0)tfuγm1=Vb⇒p=18+66.14×1030.9×12×410/1.25=36.7 mm\frac{0.9(p-d_0)tf_u}{\gamma_{m1}}=V_b\Rightarrow p=18+\frac{66.14\times10^3}{0.9\times12\times410/1.25}=36.7\ \text{mm}

This is below the minimum pitch 2.5d=402.5d=40 mm, so take p=40p=40 mm. Check:

  • Net strength of plate in a pitch strip: Tdn=0.9(40−18)×12×4101.25=77.9T_{dn}=\dfrac{0.9(40-18)\times12\times410}{1.25}=77.9 kN >Vb>V_b
  • Gross strength of plate in a pitch strip: Tdg=40×12×2501.10=109.1T_{dg}=\dfrac{40\times12\times250}{1.10}=109.1 kN

Efficiency

η=lesser of bolt value and TdnTdg=66.14109.1×100=60.6%\eta=\frac{\text{lesser of bolt value and }T_{dn}}{T_{dg}}=\frac{66.14}{109.1}\times100=60.6\%

Answer: M16 bolts at 40 mm pitch in one row, end distance 30 mm, with 8 mm cover plates on both sides; efficiency ≈61%\approx61\%. (A single row cannot do better than this; efficiency can be raised by using more rows of bolts in a zig-zag pattern.)