Double cover butt joint, M16 class 10.9

Short answer

Provide 4 M16 HSFG bolts of class 10.9 on each side in a single line at 50 mm pitch, with 12 mm cover plates on both faces.

Design a double cover butt joint to transmit a working load of 300KN to connect two flats 100mm wide and 20mm thick using M16 high strength bolts of property class 10.9 if slip is permitted at design load. The cover plates are 12 mm thick. Assume that one shear plane intercepts the threads of the bolts.

Data: working load 300 kN → factored Pu=1.5×300=450P_u=1.5\times300=450 kN. Flats 100×20 mm, covers 12 mm each, M16 HSFG bolts of class 10.9 (fub=1000f_{ub}=1000 N/mm²), d0=18d_0=18 mm, E250. "Slip permitted at design load" means the bolts are designed as bearing-type (for shear and bearing, IS 800:2007 cl. 10.3/10.4). Double shear, with one plane through the threads.

Bolt value

  • Shear: Vdsb=fub3γmb(Anb+Asb)=10003×1.25(157+201)×10−3=165.35V_{dsb}=\dfrac{f_{ub}}{\sqrt3\gamma_{mb}}(A_{nb}+A_{sb})=\dfrac{1000}{\sqrt3\times1.25}(157+201)\times10^{-3}=165.35 kN
  • Bearing on the 20 mm flat (e=30e=30, p=50p=50): kb=min⁡(0.556, 0.676, 2.44, 1)=0.556k_b=\min(0.556,\ 0.676,\ 2.44,\ 1)=0.556
Vdpb=2.5kbdtfuγmb=2.5×0.556×16×20×4101.25×10−3=145.8 kNV_{dpb}=\frac{2.5k_bdtf_u}{\gamma_{mb}}=\frac{2.5\times0.556\times16\times20\times410}{1.25}\times10^{-3}=145.8\ \text{kN}
  • Bolt value =145.8=145.8 kN (bearing governs)

Number of bolts

n=450145.8=3.08⇒n=\dfrac{450}{145.8}=3.08\Rightarrow provide 4 bolts on each side of the joint, in a single line along the centre of the flat at 50 mm pitch with 30 mm end distance, so the flat is weakened by only one hole.

Checks

  • Flat gross yielding: Tdg=100×20×2501.10=454.5T_{dg}=\dfrac{100\times20\times250}{1.10}=454.5 kN ≥450\ge450 ✓
  • Flat net rupture (1 hole): Tdn=0.9(100−18)×20×4101.25=484.1T_{dn}=\dfrac{0.9(100-18)\times20\times410}{1.25}=484.1 kN ≥450\ge450 ✓
  • Cover plates 2×12=24>202\times12=24>20 mm: Tdg=545.5T_{dg}=545.5 kN ✓
  • Bolts: 4×145.8=583.14\times145.8=583.1 kN ≥450\ge450 ✓
  • (For information, the slip resistance per bolt at service load is Vdsf=μfneKhFo/γmf=95.9V_{dsf}=\mu_f n_eK_hF_o/\gamma_{mf}=95.9 kN with μf=0.48\mu_f=0.48, ne=2n_e=2, Kh=1.0K_h=1.0, Fo=0.7fubAnb=109.9F_o=0.7f_{ub}A_{nb}=109.9 kN and γmf=1.10\gamma_{mf}=1.10; the total of 384 kN exceeds 300 kN, so the joint does not slip under the working load either.)

Answer: 4 M16 (10.9) HSFG bolts on each side in a single line at 50 mm pitch, with 12 mm cover plates on both faces.

✓ Answer checked by Claude Opus 5.5 (high effort)

All Design of Steel and Timber Structure chapter 4 questions →