Parallel pipeline to increase discharge

Short answer

Existing pipe needs 440.68 m head. For 0.1125 m³/s flow, old pipe carries 0.0595 m³/s in parallel half, new pipe must take 0.053 m³/s under same head loss, requiring diameter 0.143 m; recommend standard 150 mm.

A pipeline supplies 0.09 m³/s water from a reservoir to a building. The pipe is 2 km long and 0.15 m diameter with friction factor 0.025. It is desired to increase the discharge by 25% by installing another pipeline having same friction factor in parallel with this over half the length. Recommend a suitable diameter of the pipe to be installed.

The head available (reservoir to building) stays the same. Adding a parallel pipe over the first half reduces resistance there, so more flow passes. Darcy–Weisbach with friction factor ff is used: hf=fLV22gD=8fLQ2π2gD5h_f = \dfrac{fLV^2}{2gD} = \dfrac{8fLQ^2}{\pi^2 g D^5}.

Step 1: Available head (existing pipe)

h=8×0.025×2000×0.092π2×9.81×0.155=440.68 m\begin{aligned} h &= \frac{8 \times 0.025 \times 2000 \times 0.09^2}{\pi^2 \times 9.81 \times 0.15^5} = 440.68\ \text{m} \end{aligned}

(This large value is simply the head the original pipe needs; it stays fixed.)

Step 2: New layout

           Pipe A (0.15 m, 1000 m), Q1
 Res ==+=================================+===== 0.15 m, 1000 m ====> Bldg
       +---------------------------------+        Q = 0.1125
           Pipe B (D2, 1000 m), Q2

New discharge Q=1.25×0.09=0.1125Q = 1.25 \times 0.09 = 0.1125 m³/s.

Loss in the second (single) half:

h2=8×0.025×1000×0.11252π2×9.81×0.155=344.28 mh_2 = \frac{8 \times 0.025 \times 1000 \times 0.1125^2}{\pi^2 \times 9.81 \times 0.15^5} = 344.28\ \text{m}

Loss allowed in the parallel half:

hp=440.68−344.28=96.40 mh_p = 440.68 - 344.28 = 96.40\ \text{m}

Step 3: Flow in old pipe of the parallel portion

96.40=8×0.025×1000 Q12π2×9.81×0.155Q1=0.0595 m3/s\begin{aligned} 96.40 &= \frac{8 \times 0.025 \times 1000\,Q_1^2}{\pi^2 \times 9.81 \times 0.15^5} \\ Q_1 &= 0.0595\ \text{m}^3/\text{s} \end{aligned}

So the new pipe must carry Q2=0.1125−0.0595=0.0530Q_2 = 0.1125 - 0.0595 = 0.0530 m³/s.

Step 4: Diameter of new pipe

Same ff, same length and same head loss hph_p, so Q∝D2.5Q \propto D^{2.5}:

D2=0.15(Q2Q1)0.4=0.15(0.05300.0595)0.4=0.143 m\begin{aligned} D_2 &= 0.15\left(\frac{Q_2}{Q_1}\right)^{0.4} = 0.15\left(\frac{0.0530}{0.0595}\right)^{0.4} = 0.143\ \text{m} \end{aligned}

Answer: A parallel pipe of about 0.143 m diameter is needed. Recommend the next standard size, 150 mm, which gives slightly more than the required 25% increase.