- 2071 Bhadra · 3+3 marks
Gauging site selection and current meter use
Short answer
Select a straight, stable channel with a well-defined control and no backwater effects. Current meter procedure: divide cross-section, measure depth, lower meter to 0.6d (or 0.2d and 0.8d), count revolutions per second, convert to velocity using V=aN+b, then compute discharge by mid-section method.
What factors should be considered in selecting a site for a stream gauging station? Describe briefly the procedure of using a current meter for measuring velocity of stream.
Factors for selecting a stream gauging site
- Straight reach: about 5–10 times the river width upstream and downstream, with parallel flow lines.
- Stable channel: bed and banks free from scour, deposition and shifting, so the stage–discharge relation stays constant.
- Well-defined control (rock bar, rapids or a weir) downstream, giving a unique stage–discharge relation.
- No backwater effect from confluences, dams or tides; no eddies or dead water.
- Flow contained in one channel at all stages, without overflow at floods.
- Adequate depth and velocity for the current meter in the dry season.
- Easy access in all seasons and safe working (bridge, cableway).
- Away from tributaries, so the measured flow represents the site of interest (e.g. near the intake for a hydropower project).
Measuring velocity with a current meter
A current meter (cup type or propeller type) has a rotor whose speed of rotation is proportional to water velocity. Its calibration equation is .
Procedure:
- Stretch a tag line across the river and divide the width into 15–25 segments (each carrying ≤ 10% of flow).
- At each vertical, measure the depth with a sounding rod or weight.
- Lower the meter (wading rod for shallow water; cable, weight and cableway or bridge for deep water) to the required depth:
- Shallow (< 0.6–1 m): one reading at 0.6y from the surface.
- Deeper: two readings at 0.2y and 0.8y; mean .
- Allow the meter to settle, then count the revolutions over a fixed time (40–100 s). = revolutions/time.
- Convert to velocity with the rating equation, e.g. .
- Compute discharge by the mid-section or mean-section method: .
tag line 0 1 2 3 4 5
~~~~~~~~~~|~~~|~~~|~~~|~~~|~~~|~~~~
\ o o o o o / o = meter at 0.6y
\_______o___o___o___o_________/ or 0.2y & 0.8y
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Stream discharge from current meter revolutions (V = 0.51N + 0.03) · Hydro Power, chapter 2 · asked 2×
- Stream discharge from current meter revolutions (v = 0.55N + 0.04) · Hydro Power, chapter 2 · asked 2×
- Stream gauging with calibration equation · Hydro Power, chapter 2
- Intake site selection for RoR plant · Hydro Power, chapter 5
- Factors in selecting a gauging station site · Engineering Hydrology, chapter 4 · asked 4×
- Discharge from current meter at 0.6d, stream gauging data · Engineering Hydrology, chapter 4
- Reservoir intake and site selection factors · Water Supply Engineering, chapter 5 · asked 2×
- Distribution substation site selection factors · Industrial Power Distribution and Illumination, chapter 4