Skip to main content

Factors affecting sewage; calculating discharge

What are the various factors affecting the discharge of sanitary sewage? How do you calculate sanitary sewage discharge?

Factors affecting discharge

  1. Population and its density, and the future growth over the design period.
  2. Rate of water supply (sewage is 75-80% of supply).
  3. Type of area (residential, commercial, industrial) and standard of living.
  4. Private and public water supplies, and water metering.
  5. Groundwater infiltration, depending on water table and condition of joints.
  6. Unauthorised connections (roof, yard drains).
  7. Climate, season and hour of the day.

Calculation of sanitary sewage discharge

  1. Design population PP at the end of the design period (20-30 years), by arithmetic, geometric or incremental increase method.
  2. Average sewage flow:
Qavg=P×q×0.886400  l/sQ_{avg} = \frac{P \times q \times 0.8}{86400}\ \ \text{l/s}

where qq = water supply (lpcd) and 0.8 = fraction becoming sewage. 3. Peak (maximum) flow: Qmax=PF×QavgQ_{max}=\text{PF}\times Q_{avg}. The peak factor is 2 to 3 (about 3 for small, 2 for big towns; or by Harman's formula PF=1+144+P/1000PF = 1+\dfrac{14}{4+\sqrt{P/1000}}). 4. Minimum flow is about 13Qavg\tfrac13 Q_{avg} (used to check the self-cleansing velocity). 5. Add infiltration (e.g. 5,000-15,000 l/day/km per cm diameter of sewer, or a percentage) and industrial flows if present.

Design discharge = peak sewage flow + infiltration (+ storm runoff CiA/360CiA/360 for combined systems).

✓ Answer checked by Claude Opus 5.5 (high effort)

All Sanitary Engineering chapter 2 questions →