Estimating sewage quantity for a city

Short answer

Project design population by arithmetic or geometric method. Compute average sewage flow as 0.8×P×q/86400 l/s with q=45-135 lpcd. Apply peak factor 2-3 for max flow, add infiltration (5-10% of DWF) and industrial waste. For combined systems, add storm runoff from rational method with DHM intensity. Example: P=60,000, q=135 lpcd, PF=3 yields Qmax=225 l/s.

Describe the method of estimating the quantity of sewage for a city in Nepal in detail.

The quantity of sewage is estimated from the future population, the water supply per capita, and the factors that raise or reduce the flow. For a city in Nepal (e.g. Pokhara, Biratnagar) the method is as follows.

Step 1: Design population

Collect census data (CBS, Nepal) and project the population for the design period (about 20-25 years after completion) using the arithmetic, geometric or incremental increase method:

  • Arithmetic: Pn=P0+nxˉP_n = P_0 + n\bar{x}
  • Geometric: Pn=P0(1+r/100)nP_n = P_0(1+r/100)^n

Add floating population (tourists, commuters, students) if large.

Step 2: Water supply rate

Use the design water demand of the city (Nepal Water Supply Corporation/NWSC design guidelines): 45 lpcd for rural and 85-135 lpcd for urban areas, with additions for institutional, commercial and industrial demand and leakage.

Step 3: Average sewage flow

About 80% of supply returns as sewage (the rest is lost in gardening, evaporation, leakage and consumption):

Qavg=0.8 P q86400  l/sQ_{avg}=\frac{0.8\,P\,q}{86400}\ \ \text{l/s}

Step 4: Peak and minimum flow

  • Peak factor 2 to 3 (higher for small towns); Qmax=PF⋅QavgQ_{max}=PF\cdot Q_{avg} for sewer design.
  • Minimum flow about 13Qavg\tfrac13 Q_{avg} for velocity check at start of the design period.

Step 5: Additions

  • Infiltration depending on groundwater table and pipe quality (about 5-10% of DWF in Nepali cities, or 5,000-10,000 l/km/day/cm diameter).
  • Industrial wastewater from large industries (from their own records).
  • Storm water with Qs=CiA360Q_s=\dfrac{CiA}{360} if the system is combined or partially separate. The intensity for the Nepal city is taken from the DHM intensity-duration-frequency curves, with tc=te+tft_c=t_e+t_f.

Step 6: Design discharge

Qdesign=Qmax+Qinfiltration+Qindustrial (+Qstorm)Q_{design} = Q_{max} + Q_{infiltration} + Q_{industrial}\ (+Q_{storm})

The sewers are designed for QdesignQ_{design} at the end of the design period and checked for minimum flow at the beginning (velocity at least 0.6 m/s).

Example

For P=60,000P=60{,}000, q=135q=135 lpcd, PF = 3: Qavg=0.8×60000×135/86400=75Q_{avg}=0.8\times60000\times135/86400=75 l/s and Qmax=225Q_{max}=225 l/s.

✓ Answer checked by Claude Opus 5.5 (high effort)