- 2067 Asar (old course) · 8 marks
Load combinations for column per IS 456
Short answer
Column 400×600mm, leff=3.6m, DL=250kN, LL=100kN, wind UDL=5kN/m. Wind force=18kN, fixed-end moment=5.4kNm. IS 456 load combinations: 1) 1.5(DL+LL)=525kN, M=0; 2) 1.2(DL+LL±WL)=420kN, M=±6.48kNm, H=±21.6kN; 3) 1.5(DL±WL)=375kN, M=±8.10kNm, H=±27kN; 4) 0.9DL±1.5WL=225kN, M=±8.10kNm, H=±27kN. Check all four.
A reinforced concrete column of a moment resisting frame has its cross section 400 mm x 600 mm and effective height 3.6 m. The column has to carry loading combination of dead load, live load and moment due to wind load. The computed dead load and live load on column are 250 kN and 100 kN respectively, whereas the induced horizontal load on column due to wind load is 5 kN/m. Calculate loading combination values for all possible loading combinations as per IS 456.
Given: column 400 x 600 mm, effective height m, kN, kN, wind UDL kN/m along the height.
Wind effect on the column
- Total horizontal force: kN.
- The column is part of a moment resisting frame, so it is assumed fixed at both ends under the lateral UDL (assumption). Fixed-end moment: kN·m (wind can act in either direction, so the moment can be ).
Load combinations (IS 456:2000, Table 18 / cl. 36.4)
| No. | Combination | Axial (kN) | Moment (kN·m) | Shear (kN) |
|---|---|---|---|---|
| 1 | 525 | 0 | 0 | |
| 2 | 420 | 6.48 | 21.6 | |
| 3 | 375 | 8.10 | 27 | |
| 4 | 225 | 8.10 | 27 |
Working:
Combination 4 applies where stability against overturning or stress reversal is critical (minimum axial load with maximum moment).
Answer: Combination 1 gives the maximum axial load ( kN, apart from the minimum eccentricity moment); combination 2 gives kN with kN·m; combinations 3 and 4 give the maximum moment ( kN·m) with kN and kN. No single case can be assumed to govern, so the column is checked for all four and the worst case is adopted.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Bent-up bars, 600 mm effective depth · Design of RCC Structure, chapter 5 · asked 2×
- Check column 600x400 with 8-28 mm bars · Design of RCC Structure, chapter 10
- Rectangular column with working-load moment · Design of RCC Structure, chapter 10
- Square column with 80 mm eccentricity · Design of RCC Structure, chapter 10
- Ultimate moment of L-beam, doubly reinforced · Design of RCC Structure, chapter 4
- Moment of resistance of doubly reinforced beam · Design of RCC Structure, chapter 4
- Reinforced concrete column stresses in steel and concrete · Strength of Materials, chapter 3
- Cross wall design, 120 mm slab, 3 m wide · Concrete Technology and Masonry Structure, chapter 8 · asked 4×
- Interior cross wall design: three-storey, 150 mm slab · Concrete Technology and Masonry Structure, chapter 8 · asked 2×
- Tubular column load and eccentric loading · Strength of Materials, chapter 10