- Practice · 4+4 marks
High-volume sampler and concentration calculation
Short answer
The mass of particulates collected (0.197 g) divided by the sampled air volume (2160 m3) gives TSP concentration of 91.2 μg/m3. SO2 concentration is converted using C = (ppm × MW × 1000) / molar volume, yielding 131 μg/m3.
(a) Describe the principle and working of a high-volume (hi-vol) sampler used for measuring suspended particulate matter. (b) A hi-vol sampler runs for 24 hours at a mean flow rate of 1.5 m3/min. The filter weighs 3.215 g before and 3.412 g after sampling. Calculate the TSP concentration in micrograms per cubic metre. Also convert an SO2 reading of 0.05 ppm to micrograms per cubic metre at 25 degrees C and 1 atm (molecular weight of SO2 = 64.06; molar volume = 24.45 L/mol).
(a) High-volume sampler
Principle: a large volume of air is drawn through a pre-weighed filter. Particles are retained on the filter, and the mass gained divided by the air volume gives the concentration.
rain-proof roof
________________
/ air inlet gap \
/__________________\
| filter paper | (20 x 25 cm glass fibre)
|______________|
| support |
|______________|
| blower + |--> flow meter / recorder
| motor |
|______________|
Working:
- A conditioned glass-fibre filter is weighed () and placed in the holder.
- A motor-driven blower draws air at about 1.1-1.7 /min through the filter. The roof keeps out rain and large particles (about > 100 m).
- The flow rate is recorded at the start and end (or continuously) and the mean value used.
- After 24 h the filter is conditioned and re-weighed ().
Concentration . It measures total suspended particulates (TSP); a PM10 inlet can be fitted for PM10.
(b) Numerical
Volume of air sampled:
Mass of particulates:
SO conversion:
(0.05 ppm = mol per mol of air; 1 ppm of a gas = .)
Answer: TSP = 91.2 g/m; 0.05 ppm SO = 131 g/m.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Landfill volume and area calculation · Environment and Pollution Control, chapter 5
- BOD versus COD and a BOD and COD calculation · Environment and Pollution Control, chapter 4
- Storage for uniform inflow over 24 hours · Water Supply Engineering, chapter 7
- Recirculation ratio, filter volume 510 m³ · Sanitary Engineering, chapter 7
- Recirculation ratio, filter volume 350 m³ · Sanitary Engineering, chapter 7