- 2074 Bhadra · 8 marks
Recirculation ratio, filter volume 510 m³
Short answer
Recirculation ratio required is about 4.5, determined from NRC equation with required efficiency 79.17% and factor F = 2.616.
If the effluent BOD is to be equal to or less than 35 mg/l, what will be the recirculation ratio required of a single high rate trickling filter having volume of 510 m³ which receives a flow of 2.8 MLD. The raw sewage has BOD of 210 mg/l. The primary treatment removes 20% BOD.
Data and approach
NRC equation for a high-rate filter: , with ( in kg/day, in m³).
Step 1: BOD load and required efficiency
Step 2: Required recirculation factor
Let :
Step 3: Recirculation ratio
(The other root, , lies beyond , where is at its maximum, and is not used.)
Check: and , equal to the required 79.17%.
Answer: recirculation ratio required (about 4.5).