Standard rate trickling filter, 3 MLD, 300 mg/l
Short answer
Volume = 3000 m³, depth = 3.00 m, area = 1000 m²; NRC efficiency = 80.47%.
The effluent from PST is applied to a standard rate trickling filter at the rate of 3 million liters/day with BOD5 300 mg/l. Calculate the depth and volume of filter considering the surface loading of 3000 liters/m²day and organic loading of 300 gm/m³day.
Data: l/day m³/day, settled-sewage BOD mg/l, surface loading l/m²/day, organic loading g/m³/day. (The NRC efficiency is also given below for completeness.)
Step 1: BOD load
Step 2: Volume (organic loading 300 g/m³/day)
Step 3: Area (hydraulic loading 3000 l/m²/day) and depth
Diameter of the circular filter: m.
Step 4: Efficiency by the NRC equation (no recirculation, )
Effluent BOD mg/l.
Answer: volume m³; depth m; area m²; NRC efficiency .