Standard rate trickling filter, 1.2 MLD, NRC
Short answer
From organic loading 250 g/m³·d and surface loading 1200 L/m²·d, volume is 960 m³ and area 1000 m², giving depth 0.96 m. NRC efficiency (no recirculation) is 81.86%, yielding an effluent BOD of 36.3 mg/l.
The effluent from PST is applied to a standard rate trickling filter at the rate of 1.2 million liters/day having BOD5 of 200 mg/l. Determine the depth and volume of filter considering surface loading of 1200 liters/m².day and organic loading of 250 gm/m³.day. Also, calculate the efficiency of filter using NRC equation.
Data
Flow l/day m³/day; influent BOD (after PST) mg/l; surface (hydraulic) loading l/m²/day; organic loading g/m³/day.
Step 1: BOD load
Step 2: Volume (from organic loading)
Step 3: Surface area (from hydraulic loading)
Step 4: Depth
(Diameter of the circular filter m. The calculated depth is smaller than the usual 1.8-3 m of a standard-rate filter; if a depth of 1.8 m is wanted, the area is reduced to 533 m² and the hydraulic loading rises accordingly.)
Step 5: Efficiency by the NRC equation (standard rate, no recirculation, )
Effluent BOD mg/l.
Answer: volume m³, depth m (area 1000.0 m²); NRC efficiency .
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Standard rate trickling filter, 3 MLD, 300 mg/l · Sanitary Engineering, chapter 7 · asked 3×
- Standard rate trickling filter, 4 MLD, NRC · Sanitary Engineering, chapter 7
- Standard rate filter, 3 MLD, 175 mg/l, NRC · Sanitary Engineering, chapter 7
- HR trickling filter, 2.5 MLD; change if standard · Sanitary Engineering, chapter 7
- Two-stage trickling filter diameters, 4 MLD · Sanitary Engineering, chapter 7 · asked 2×
- Two-stage trickling filter diameters, 5 MLD · Sanitary Engineering, chapter 7 · asked 2×
- Two-stage trickling filter, 7665 m³/day · Sanitary Engineering, chapter 7