Two-stage trickling filter, 7665 m³/day
Short answer
After 35% primary removal, applied BOD is 123.5 mg/l, overall filter efficiency 79.76%. Assuming equal stage efficiencies of 55.01%, recirculation factor 1.3605, volumes 204.3 m³ and 454.1 m³ yield diameters 11.9 m and 17.7 m.
A municipal wastewater having a BOD5 of 190 mg/l is to be treated by a two stage trickling filter. The desired BOD5, 20°C of the final effluent is to be 25 mg/l. If both the filter's depth is to be 1.85 m and recirculation ratio for both filters is 0.5, determine the required filter diameters. Assume the wastewater flow rate of 7665 m³/day, and 35% BOD is removed in primary sedimentation tank.
Data: m³/day; raw BOD mg/l; 35% removed in the primary sedimentation tank, so BOD to the filters mg/l; final BOD mg/l; depth m; for both filters.
Data and approach
Two-stage filter (NRC equations, in kg/day, in m³):
where is the BOD load leaving the first stage ( as a fraction in the second equation). Flow m³/day.
Step 1: Loads and efficiencies
No ratio is given, so both stages are taken to have equal efficiency : , i.e. .
Step 2: Recirculation factor (same for both stages, )
Step 3: First stage
Step 4: Second stage
Step 5: Diameters (depth m)
Answer: first-stage filter m (volume 204.3 m³); second-stage filter m (volume 454.1 m³).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Effluent BOD of two-stage trickling filter · Sanitary Engineering, chapter 7
- Two-stage trickling filter diameters, 4 MLD · Sanitary Engineering, chapter 7 · asked 2×
- Two-stage trickling filter diameters, 5 MLD · Sanitary Engineering, chapter 7 · asked 2×
- HR trickling filter, BOD 280 mg/l · Sanitary Engineering, chapter 7
- HR trickling filter, 2.5 MLD; change if standard · Sanitary Engineering, chapter 7
- Recirculation ratio, filter volume 510 m³ · Sanitary Engineering, chapter 7
- Municipal wastewater treatment plant · Environment and Pollution Control, chapter 4