- 2076 Baisakh · 8 marks
HR trickling filter, BOD 280 mg/l
Short answer
Single-stage high-rate filter volume 5974.6 m³, depth 2.0 m, diameter 61.7 m; in practice use two filters of 43.6 m diameter each.
Raw sewage contain BOD of 280 mg/l with flow of 5 MLD is required to be treated through a single stage high rate trickling filter to convert effluent BOD of 25 mg/l to dispose off in the nearby river. Assuming that the primary sedimentation tank removes 25% of BOD, propose the dimension of filter with recirculation ratio of 1.5.
Data and approach
High-rate filter design uses the NRC (National Research Council) equation; is in kg/day of BOD applied to the filter, in m³:
Step 1: BOD applied to the filter and required efficiency
Step 2: Recirculation factor
Step 3: Volume
Step 4: Diameter
Adopt depth m (high-rate filters are 1.8-3 m deep).
Step 5: Checks
Both loadings are below the usual high-rate range. This is because a single stage must give the high efficiency of 88%, so the NRC equation requires a large volume. A diameter of 61.7 m is also more than the usual maximum of about 60 m for a rotary distributor. In practice, provide two filters in parallel, each of area m² and diameter m (depth 2.0 m), or use a two-stage filter.
Answer: single-stage high-rate filter of volume about 5974.6 m³, depth 2.0 m, diameter 61.7 m (in practice 2 filters of 43.6 m diameter each).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Effluent BOD of two-stage trickling filter · Sanitary Engineering, chapter 7
- HR trickling filter, 5 MLD, RR 1.5 · Sanitary Engineering, chapter 7 · asked 2×
- HR trickling filter, 5 MLD, RR 1.3 · Sanitary Engineering, chapter 7
- HR trickling filter, 2.5 MLD; change if standard · Sanitary Engineering, chapter 7
- Two-stage trickling filter diameters, 4 MLD · Sanitary Engineering, chapter 7 · asked 2×
- Two-stage trickling filter diameters, 5 MLD · Sanitary Engineering, chapter 7 · asked 2×
- Rapid sand filter design for 25 MLD · Water Supply Engineering, chapter 6