HR trickling filter, 5 MLD, RR 1.5
Short answer
Using the NRC equation with BOD load after primary 875 kg/d, required efficiency 82.86%, and recirculation factor F=1.89, the required filter volume is 2124 m³. Depth 2.0 m gives a diameter of 36.8 m.
Determine the size of a high-rate single stage trickling filter for the following data: Sewage flow = 5 MLD; Recirculation ratio = 1.5; BOD of raw sewage = 250 mg/l; BOD removal in primary clarifier = 30%; Final effluent BOD desired = 30 mg/l.
Data and approach
High-rate filter design uses the NRC (National Research Council) equation; is in kg/day of BOD applied to the filter, in m³:
Step 1: BOD applied to the filter and required efficiency
Step 2: Recirculation factor
Step 3: Volume
Step 4: Diameter
Adopt depth m (high-rate filters are 1.8-3 m deep).
Step 5: Checks
The organic loading comes out below the usual high-rate range because a single stage has to give a high efficiency (about 83%); the hydraulic loading is within the high-rate range.
Answer: single-stage high-rate filter of volume about 2124.0 m³, depth 2.0 m, diameter 36.8 m.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- HR trickling filter, 5 MLD, RR 1.3 · Sanitary Engineering, chapter 7
- HR trickling filter, BOD 280 mg/l · Sanitary Engineering, chapter 7
- HR trickling filter, 2.5 MLD; change if standard · Sanitary Engineering, chapter 7
- Effluent BOD of two-stage trickling filter · Sanitary Engineering, chapter 7
- Recirculation ratio, filter volume 510 m³ · Sanitary Engineering, chapter 7
- Two-stage trickling filter diameters, 4 MLD · Sanitary Engineering, chapter 7 · asked 2×