- 2076 Bhadra · 8 marks
HR trickling filter, 2.5 MLD; change if standard
Short answer
High-rate filter volume 1363.8 m³, depth 2.0 m, diameter 29.5 m. If designed as standard-rate, diameter must be increased by 37.5% (to 40.5 m).
Determine the dimensions of a high rate trickling filter for the following data: (i) Sewage flow = 2.5 MLD; (ii) Recirculation ratio = 1.5; (iii) BOD of raw sewage = 300 mg/l; (iv) BOD removal in primary settling tank = 30%; (v) Final effluent BOD desired = 35 mg/l. By what % the diameter of the filter will have to be modified if it is to be designed as a standard rate trickling filter for above requirements?
Data and approach
High-rate filter design uses the NRC (National Research Council) equation; is in kg/day of BOD applied to the filter, in m³:
Step 1: BOD applied to the filter and required efficiency
Step 2: Recirculation factor
Step 3: Volume
Step 4: Diameter
Adopt depth m (high-rate filters are 1.8-3 m deep).
Step 5: Checks
Answer: single-stage high-rate filter of volume about 1363.8 m³, depth 2.0 m, diameter 29.5 m.
Change in diameter if designed as a standard-rate filter
A standard-rate filter has no recirculation (, ). The same efficiency (same ) then needs
With the same depth of 2.0 m, m, compared with m for the high-rate filter.
The diameter must be increased by about 37.5% if the filter is built as a standard-rate unit.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- HR trickling filter, BOD 280 mg/l · Sanitary Engineering, chapter 7
- Standard rate trickling filter, 3 MLD, 300 mg/l · Sanitary Engineering, chapter 7 · asked 3×
- HR trickling filter, 5 MLD, RR 1.5 · Sanitary Engineering, chapter 7 · asked 2×
- Standard rate trickling filter, 4 MLD, NRC · Sanitary Engineering, chapter 7
- HR trickling filter, 5 MLD, RR 1.3 · Sanitary Engineering, chapter 7
- Recirculation ratio, filter volume 510 m³ · Sanitary Engineering, chapter 7