Three-phase bridge inverter, 120° conduction
Short answer
In 120° conduction mode, each thyristor conducts for 120° and only two thyristors (one upper, one lower in different legs) conduct at any time. Firing sequence is T1 to T6 at 60° intervals, giving phase voltages +Vdc/2, 0, -Vdc/2 and six-step line voltages with levels Vdc, Vdc/2, -Vdc/2, -Vdc.
Discuss the principle of working of a three-phase bridge inverter with an appropriate circuit diagram. Draw phase and line voltage waveforms on the assumption that each thyristor conducts for 120° and the resistive load is star-connected. The sequence of firing of various SCRs should also be indicated in the diagram.
A three-phase bridge inverter converts dc into three-phase ac using six thyristors (with commutation circuits) or self-commutated switches, and six feedback diodes. In the 120° conduction mode each thyristor conducts for 120°, only two thyristors (one upper and one lower, in different legs) conduct at any time, and a new thyristor is fired every 60° in the order T1, T2, T3, T4, T5, T6.
Circuit
+-----+--------+--------+
| | | |
| T1 D1 T3 D3 T5 D5
Vdc | | |
| +--a +--b +--c
| | | |
| T4 D4 T6 D6 T2 D2
| | | |
+-----+--------+--------+
a, b, c -> star load (R per phase)
T1, T3, T5 connect phases a, b, c to the positive bus; T4, T6, T2 connect them to the negative bus. The numbering gives the firing sequence T1 → T2 → … → T6 at 60° intervals.
Principle of working
- In each 60° interval, one phase is connected to the positive bus, one to the negative bus, and the third is left open (floating).
- The two connected phases are in series across , so each carries , and their phase voltages are and ; the open phase has 0 V (resistive load).
- There is a 60° gap between the turn-off of the upper switch and the turn-on of the lower switch of the same leg, so the risk of shoot-through is low.
| Mode | Conducting | |||||
|---|---|---|---|---|---|---|
| 1 | 0–60° | T6, T1 | 0 | |||
| 2 | 60–120° | T1, T2 | 0 | |||
| 3 | 120–180° | T2, T3 | 0 | |||
| 4 | 180–240° | T3, T4 | 0 | |||
| 5 | 240–300° | T4, T5 | 0 | |||
| 6 | 300–360° | T5, T6 | 0 |
(.)
Firing sequence and waveforms
wt 0 60 120 180 240 300 360
T1 ##########
T2 ##########
T3 ##########
T4 ##########
T5 ##########
T6 ##### #####
van V/2 __________
0 |____ ____
-V/2 |_________|
vbn V/2 _________
0 ____| |____
-V/2 _____| |____
vcn V/2 _________
0 _____ ____|
-V/2 |_________|
vab V _____
V/2 |____ ____
0 | |
-V/2 |____ ____|
-V |____|
- Phase voltage : for 120°, 0 for 60°, for 120°, 0 for 60° (quasi-square). and lag it by 120° and 240°.
- Line voltage : six-step wave with levels , , , , , .
Main results
Only harmonics of order are present. Compared with the 180° mode, switch utilisation and output voltage are lower, and with an inductive load the voltage of the open phase is not zero (it depends on the load), which is a drawback.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Three-phase bridge inverter 180° and 120° numerical · Power Electronics, chapter 5
- Three-phase six-step (180° conduction) inverter · Power Electronics, chapter 5 · asked 4×
- Bridge single-phase cycloconverter conduction sequence · Power Electronics, chapter 6 · asked 3×
- 180° three-phase inverter and fundamental phase voltage · Power Electronics, chapter 5
- Half-bridge square-wave inverter at 120 Hz · Power Electronics, chapter 5
- Three-phase fully controlled bridge with R load · Power Electronics, chapter 3
- 3-phase thyristor bridge: no-load speed and firing angle · Utilization of Electrical Energy, chapter 3 · asked 3×
- 3-phase half controlled bridge: no-load speed, firing angle · Utilization of Electrical Energy, chapter 3 · asked 3×
- Star load (8+j6) line, phase current · Basic Electrical Engineering, chapter 8
- Chopper definition; single-phase half bridge inverter · Advanced Electronics, chapter 7