- Asked 3/23
- 2076 Chaitra · 8 marks
- 2072 Kartik · 8 marks
Three-phase single-way controlled rectifier, α = 60°
Short answer
Each thyristor conducts for 120° after firing at α from its natural commutation point. Average output voltage Vdc = (3√3 Vm)/(2π) cos α = 0.827 Vm cos α; for α=60°, Vdc = 0.4135 Vm.
Explain the operation of a three phase single way controlled rectifier circuit with highly inductive load. Derive the expression for average value of the output voltage. Draw the wave form of output voltage for firing angle of 60°.
A three-phase single-way (half-wave, three-pulse) controlled rectifier uses three thyristors, one per phase, connected to a star-connected supply (or transformer secondary) with the load returned to the neutral. The output voltage is controlled by delaying the firing of each thyristor by from its natural commutation point.
T1
a o------>|-----+
T2 |
b o------>|-----+------o P (+)
T3 | |
c o------>|-----+ Load
|
n o----------------------o N (-)
a, b, c, n: star-connected secondary
va = Vm sin wt, vb lags 120, vc lags 240
Operation
- Each thyristor's anode goes to one phase and the cathodes are joined to the positive output. A thyristor can conduct only when its phase is the most positive and it has been fired.
- The firing angle is measured from the natural commutation point (the instant a diode would start conducting), i.e. from after the zero crossing of its phase voltage. So T1 is fired at , T2 at , T3 at .
- When T2 is fired, , so T1 becomes reverse biased and turns off (natural/line commutation).
- With a highly inductive load, the load current is continuous and constant, so each thyristor conducts for exactly , even if its phase voltage becomes negative. The output follows the phase of the conducting thyristor.
| Interval () | Conducting | |
|---|---|---|
| – | T1 | |
| – | T2 | |
| – | T3 |
Waveform for α = 60°
phase: va vb vc
fired at: 90 210 330 (deg)
ends at: 210 330 450
each phase is used from 90 to 210 deg of its
own sine; vo goes negative for the last
30 deg of every 120 deg pulse
vo
|`-. |`-. |`-.
| `-. | `-. | `-.
-----+------`-.-----+------`-.-----+------`-.
`-. | `-. | `-.
90 180 210 330 450
each pulse: Vm (at 90) -> 0 (at 180)
-> -0.5 Vm (at 210), then jumps to next phase
Average output voltage
Taking the conduction of T1 (the waveform repeats every ):
where is the peak phase voltage. Maximum value (at ) is , so .
- : , rectifier mode.
- : .
- : , inverter mode (needs a dc source in the load).
For : . (E.g. with 230 V per phase, V and V.)
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Three-phase single-way controlled rectifier, α = 90° · Power Electronics, chapter 3 · asked 4×
- Three-phase single-way controlled rectifier, α = π/6 · Power Electronics, chapter 3
- Three-phase single-way controlled rectifier, R load · Power Electronics, chapter 3 · asked 3×
- Three-phase single-way controlled rectifier, α = 30° · Power Electronics, chapter 3 · asked 4×
- Three-phase single-way controlled rectifier · Power Electronics, chapter 3 · asked 3×
- Three-phase single-way thyristor rectifier: average · Power Electronics, chapter 3 · asked 3×
- Three-phase single-way thyristor rectifier: average and RMS · Power Electronics, chapter 3 · asked 5×
- 3-phase half controlled bridge: no-load speed, firing angle · Utilization of Electrical Energy, chapter 3 · asked 3×
- SCR analogy; half-wave rectifier for 1 A average · Advanced Electronics, chapter 7
- 3-phase thyristor bridge: no-load speed and firing angle · Utilization of Electrical Energy, chapter 3 · asked 3×
- Voltage regulation expression for inductive load · Electrical Machines, chapter 2