- Asked 2/22
- 2074 Chaitra · 10 marks
Combined cycle advantages and three designs
Short answer
Combined cycle gives 50-60% efficiency, lower fuel cost, capital cost, construction time, cooling water and emissions, plus fast start and flexibility. Three popular designs: unfired or supplementary-fired HRSG; exhaust used as combustion air in a fired boiler; exhaust used to heat feed water.
What are the advantages of gas and steam combined cycle? Briefly explain the three popular designs of the combination cycles.
A gas and steam combined cycle joins a gas turbine (topping) cycle with a steam (bottoming) cycle. The GT exhaust heat produces steam, so the same fuel produces more power.
Advantages
- High overall efficiency (50-60%) against 35-40% for steam and 30-38% for gas turbine plants, so lower fuel cost per kWh.
- Lower capital cost per kW than coal or nuclear plants; the gas turbine part is compact and factory built.
- Short construction time (2-3 years); can be built in phases (gas turbine runs first in open cycle).
- Quick start-up and good load-following, so useful for intermediate and peak loads as well as base load.
- Less cooling water needed, since only the steam part (about one-third of output) has a condenser.
- Lower emissions of CO2, SO2 and particulates per kWh (usually natural gas fuel); no ash handling.
- Less space and smaller staff; high reliability and availability.
- Flexible: supplementary firing, cogeneration (process steam), repowering of old steam plants.
Three popular designs
Design 1: Unfired (or supplementary fired) heat recovery boiler (HRSG)
air 1 fuel
| |
v v
+------+ 2 +-----------+ 3 +------+
| Comp |---------->| Combustion|------>| GT |===> G1
+------+ | chamber | +------+
|| +-----------+ || |
++=============== shaft =============++ | 4 hot exhaust
v (~500-600 C)
stack <-- 5 --+-------------------------------+
| HRSG (economiser, |
| evaporator, superheater) |
+-------------------------------+
^ d | a steam
| v
+------+ +------+
| Pump | | ST |===> G2
+------+ +------+
^ c | b
| +-----------+ |
+---| Condenser |<---+
+-----------+
The GT exhaust raises all the steam in a heat recovery boiler. A duct burner may add supplementary fuel. This is the most common modern design (efficiency 50-60%).
Design 2: Exhaust used as combustion air in a fired boiler
air fuel
|1 |
v v
[C]--2-->[CC]--3-->[GT]==> G1
| 4 hot exhaust (~15% O2)
v used as combustion air
fuel --> +-----------------+ a +----+
| Fired steam |---->| ST |==> G2
stack <----| boiler | +----+
+-----------------+ | b
^ d v
| +------+ c +-----------+
+--| Pump |<----| Condenser |
+------+ +-----------+
The hot, oxygen-rich exhaust replaces the air preheater and forced draft air of a conventional fired boiler. Steam turbine output is large compared to gas turbine output.
Design 3: Exhaust heats the feed water
air fuel
| 1 |
v v
[C]--2-->[ CC ]--3-->[GT]==> G1
|| | 4 exhaust gas
++=====shaft=========+ v
+--------------------------+
stack <-5| Feed water heater (gas |
| to water heat exchanger) |
+--------------------------+
^ d | e hot feed water
| v
+------+ +----------+ a +----+
| Pump | | Steam |---->| ST |==> G2
+------+ | boiler | +----+
^ c +----------+ | b
| ^ fuel v
| +-----------------+
+-----------| Condenser |
+-----------------+
The exhaust heats the condensate/feed water of a conventional steam plant, replacing bled-steam feed heaters; the boiler supplies the rest of the heat.
Comparison
| Design | Fuel in boiler | Main feature |
|---|---|---|
| Unfired / supp. fired HRSG | None / small | Highest efficiency (55-60%), simple |
| Exhaust-fired boiler | Full firing | Large steam output, GT exhaust replaces air preheater |
| Feed water heating | Full firing | Small gain, easy repowering of existing plant |
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Combined cycle merits, demerits and designs · Power Plant Equipment, chapter 8 · asked 2×
- Three popular combined cycle designs · Power Plant Equipment, chapter 8
- Combined plant introduction and popular designs · Power Plant Equipment, chapter 8
- Working of combined gas-steam plant · Power Plant Equipment, chapter 8
- Combined cycle components and waste heat use · Power Plant Equipment, chapter 8
- Gas vs vapor cycles; Otto cycle efficiency · Fundamental of Thermodynamics & Heat Transfer, chapter 6
- Combined cycle gas turbine versus hydro · Power Plant Design, chapter 1
- Three-process gas cycle: net work, heat, type · Fundamental of Thermodynamics & Heat Transfer, chapter 4 · asked 2×
- Three-process gas cycle: net work and heat · Fundamental of Thermodynamics & Heat Transfer, chapter 4