Skip to main content

Combined cycle advantages and three designs

Short answer

Combined cycle gives 50-60% efficiency, lower fuel cost, capital cost, construction time, cooling water and emissions, plus fast start and flexibility. Three popular designs: unfired or supplementary-fired HRSG; exhaust used as combustion air in a fired boiler; exhaust used to heat feed water.

What are the advantages of gas and steam combined cycle? Briefly explain the three popular designs of the combination cycles.

A gas and steam combined cycle joins a gas turbine (topping) cycle with a steam (bottoming) cycle. The GT exhaust heat produces steam, so the same fuel produces more power.

Advantages

  • High overall efficiency (50-60%) against 35-40% for steam and 30-38% for gas turbine plants, so lower fuel cost per kWh.
  • Lower capital cost per kW than coal or nuclear plants; the gas turbine part is compact and factory built.
  • Short construction time (2-3 years); can be built in phases (gas turbine runs first in open cycle).
  • Quick start-up and good load-following, so useful for intermediate and peak loads as well as base load.
  • Less cooling water needed, since only the steam part (about one-third of output) has a condenser.
  • Lower emissions of CO2, SO2 and particulates per kWh (usually natural gas fuel); no ash handling.
  • Less space and smaller staff; high reliability and availability.
  • Flexible: supplementary firing, cogeneration (process steam), repowering of old steam plants.

Three popular designs

Design 1: Unfired (or supplementary fired) heat recovery boiler (HRSG)

      air 1                fuel
      |                     |
      v                     v
   +------+     2     +-----------+   3   +------+
   | Comp |---------->| Combustion|------>|  GT  |===> G1
   +------+           |  chamber  |       +------+
      ||              +-----------+        ||  |
      ++=============== shaft =============++  | 4 hot exhaust
                                               v   (~500-600 C)
   stack <-- 5 --+-------------------------------+
                 |  HRSG (economiser,            |
                 |  evaporator, superheater)     |
                 +-------------------------------+
                     ^ d                  | a steam
                     |                    v
                 +------+             +------+
                 | Pump |             |  ST  |===> G2
                 +------+             +------+
                     ^ c                  | b
                     |   +-----------+    |
                     +---| Condenser |<---+
                         +-----------+

The GT exhaust raises all the steam in a heat recovery boiler. A duct burner may add supplementary fuel. This is the most common modern design (efficiency 50-60%).

Design 2: Exhaust used as combustion air in a fired boiler

  air      fuel
   |1        |
   v         v
  [C]--2-->[CC]--3-->[GT]==> G1
                      | 4 hot exhaust (~15% O2)
                      v   used as combustion air
         fuel --> +-----------------+  a  +----+
                  | Fired steam     |---->| ST |==> G2
       stack <----| boiler          |     +----+
                  +-----------------+       | b
                     ^ d                    v
                     |  +------+  c  +-----------+
                     +--| Pump |<----| Condenser |
                        +------+     +-----------+

The hot, oxygen-rich exhaust replaces the air preheater and forced draft air of a conventional fired boiler. Steam turbine output is large compared to gas turbine output.

Design 3: Exhaust heats the feed water

  air       fuel
   | 1        |
   v          v
  [C]--2-->[ CC ]--3-->[GT]==> G1
   ||                   |  4  exhaust gas
   ++=====shaft=========+  v
          +--------------------------+
 stack <-5| Feed water heater (gas   |
          | to water heat exchanger) |
          +--------------------------+
             ^ d             | e  hot feed water
             |               v
          +------+     +----------+  a  +----+
          | Pump |     |  Steam   |---->| ST |==> G2
          +------+     |  boiler  |     +----+
             ^ c       +----------+       | b
             |              ^ fuel        v
             |           +-----------------+
             +-----------|    Condenser    |
                         +-----------------+

The exhaust heats the condensate/feed water of a conventional steam plant, replacing bled-steam feed heaters; the boiler supplies the rest of the heat.

Comparison

DesignFuel in boilerMain feature
Unfired / supp. fired HRSGNone / smallHighest efficiency (55-60%), simple
Exhaust-fired boilerFull firingLarge steam output, GT exhaust replaces air preheater
Feed water heatingFull firingSmall gain, easy repowering of existing plant

✓ Answer checked by Claude Opus 5.5 (high effort)