Advantages: 50-60% efficiency, lower fuel cost, low capital cost, short construction, quick start, less cooling water, lower emissions, less space. Disadvantages: needs clean costly fuel, output falls at high ambient temperature, complex controls, frequent gas turbine hot-part inspection, limited unit size. Popular designs: HRSG, exhaust as combustion air in fired boiler, exhaust feed water heating.
What are the advantages and disadvantages of gas and steam combined cycle? Briefly discuss the popular designs of the combination cycles.
A gas and steam combined cycle uses the exhaust heat of a gas turbine to generate steam for a steam turbine, so overall efficiency becomes 50-60%.
Advantages
- High overall efficiency (50-60%) against 35-40% for steam and 30-38% for gas turbine plants, so lower fuel cost per kWh.
- Lower capital cost per kW than coal or nuclear plants; the gas turbine part is compact and factory built.
- Short construction time (2-3 years); can be built in phases (gas turbine runs first in open cycle).
- Quick start-up and good load-following, so useful for intermediate and peak loads as well as base load.
- Less cooling water needed, since only the steam part (about one-third of output) has a condenser.
- Lower emissions of CO2, SO2 and particulates per kWh (usually natural gas fuel); no ash handling.
- Less space and smaller staff; high reliability and availability.
- Flexible: supplementary firing, cogeneration (process steam), repowering of old steam plants.
Disadvantages
- Needs clean, costly fuel (natural gas or distillate oil); not suited to coal unless gasified.
- Output and efficiency fall with high ambient temperature and altitude (gas turbine takes less mass of air).
- More complex plant and controls; two kinds of machines to maintain.
- Gas turbine hot parts need frequent inspection; high-temperature materials are costly.
- Unit size limited by available gas turbine sizes.
- Part-load efficiency falls when the gas turbines run at reduced load.
Popular designs of combination cycles
Design 1: Unfired (or supplementary fired) heat recovery boiler (HRSG)
air 1 fuel
| |
v v
+------+ 2 +-----------+ 3 +------+
| Comp |---------->| Combustion|------>| GT |===> G1
+------+ | chamber | +------+
|| +-----------+ || |
++=============== shaft =============++ | 4 hot exhaust
v (~500-600 C)
stack <-- 5 --+-------------------------------+
| HRSG (economiser, |
| evaporator, superheater) |
+-------------------------------+
^ d | a steam
| v
+------+ +------+
| Pump | | ST |===> G2
+------+ +------+
^ c | b
| +-----------+ |
+---| Condenser |<---+
+-----------+
The GT exhaust raises all the steam in a heat recovery boiler. A duct burner may add supplementary fuel. This is the most common modern design (efficiency 50-60%).
Design 2: Exhaust used as combustion air in a fired boiler
air fuel
|1 |
v v
[C]--2-->[CC]--3-->[GT]==> G1
| 4 hot exhaust (~15% O2)
v used as combustion air
fuel --> +-----------------+ a +----+
| Fired steam |---->| ST |==> G2
stack <----| boiler | +----+
+-----------------+ | b
^ d v
| +------+ c +-----------+
+--| Pump |<----| Condenser |
+------+ +-----------+
The hot, oxygen-rich exhaust replaces the air preheater and forced draft air of a conventional fired boiler. Steam turbine output is large compared to gas turbine output.
Design 3: Exhaust heats the feed water
air fuel
| 1 |
v v
[C]--2-->[ CC ]--3-->[GT]==> G1
|| | 4 exhaust gas
++=====shaft=========+ v
+--------------------------+
stack <-5| Feed water heater (gas |
| to water heat exchanger) |
+--------------------------+
^ d | e hot feed water
| v
+------+ +----------+ a +----+
| Pump | | Steam |---->| ST |==> G2
+------+ | boiler | +----+
^ c +----------+ | b
| ^ fuel v
| +-----------------+
+-----------| Condenser |
+-----------------+
The exhaust heats the condensate/feed water of a conventional steam plant, replacing bled-steam feed heaters; the boiler supplies the rest of the heat.
| Design | Fuel in boiler | Main feature |
|---|---|---|
| Unfired / supp. fired HRSG | None / small | Highest efficiency, simple |
| Exhaust-fired boiler | Full firing | Large steam output, exhaust as air |
| Feed water heating | Full firing | Repowering of old steam plants |
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Combined cycle advantages and three designs · Power Plant Equipment, chapter 8 · asked 2×
- Three popular combined cycle designs · Power Plant Equipment, chapter 8
- Combined plant introduction and popular designs · Power Plant Equipment, chapter 8
- Working of combined gas-steam plant · Power Plant Equipment, chapter 8
- Combined cycle components and waste heat use · Power Plant Equipment, chapter 8
- Combined cycle combinations and advantages · Power Plant Equipment, chapter 8
- Reactors in stations: merits and demerits · Power Plant Equipment, chapter 4
- Gas vs vapor cycles; Otto cycle efficiency · Fundamental of Thermodynamics & Heat Transfer, chapter 6
- Combined cycle gas turbine versus hydro · Power Plant Design, chapter 1
- Operational characteristics of combined cycle plant · Power Plant Design, chapter 1
- Cofferdam types, uses, merits and demerits · Foundation Engineering, chapter 5 · asked 7×