Two-stroke motoring test: 2.2 kW motoring
Short answer
Motoring test gives FP=2.2 kW. BP=2π(800)(150)/60=12.57 kW, IP=14.77 kW, fuel heat=27.78 kW. Mechanical efficiency=85.10%; indicated thermal efficiency=53.16%.
A two stroke diesel engine was motored when the meter reading was 2.2 kW. Then the test on the engine was carried out for one hour and the following observations were recorded: Brake torque = 150 Nm; Speed = 800 rpm; Fuel used = 2.5 kg; calorific value of fuel = 40 MJ/kg; Determine: (a) Brake power (b) Indicated power, (c) Mechanical efficiency and (d) Indicated thermal efficiency.
In the motoring test the engine is turned by the dynamometer without fuel; the power required equals the friction power, so kW.
Data: N m, rpm, fuel = 2.5 kg in 1 h, CV = 40 MJ/kg = 40 000 kJ/kg.
(a) Brake power
(b) Indicated power
(c) Mechanical efficiency
(d) Indicated thermal efficiency
Heat supplied:
Answer: BP = 12.57 kW, IP = 14.77 kW, = 85.10 %, = 53.16 % (brake thermal efficiency would be 45.24 %).