Two-stroke motoring test: 1.5 kW motoring
Short answer
BP = 7.54 kW, IP = 9.04 kW, mechanical efficiency = 83.41%, indicated thermal efficiency = 32.30%.
A two stroke diesel engine was motored when the meter reading was 1.5 kW. Then the test on the engine was carried out for one hour and the following observations were recorded: Brake torque = 120 Nm; Speed = 600 rpm; Fuel used = 2.5 kg; calorific value of fuel = 40.3 MJ/kg; Determine: (a) Brake power, (b) Indicated power, (c) Mechanical efficiency and (d) Indicated thermal efficiency.
In a motoring test the engine is turned by the dynamometer without fuel; the power absorbed equals the friction power: kW.
Data: N m, rpm, fuel = 2.5 kg in 1 h, CV = 40.3 MJ/kg = 40 300 kJ/kg.
(a) Brake power
(b) Indicated power
(c) Mechanical efficiency
(d) Indicated thermal efficiency
Answer: BP = 7.54 kW, IP = 9.04 kW, = 83.41 %, = 32.30 % (brake thermal efficiency = 26.94 %).