Double stub advantages and matching steps

Short answer

Advantages: fixed stub positions, only lengths adjusted, easier tuner construction. Steps: normalize load impedance, convert to admittance, shift to first stub, rotate the g=1 circle by the stub spacing, move along constant-g circle to the rotated circle to find stub susceptances, then convert susceptances to stub lengths.

What are the advantages of using double stub matching over single stub matching? Explain the necessary steps for impedance matching of a load to a transmission line using double-stub matching network with an appropriate example. Use provided Smith Chart.

Advantages of double-stub over single-stub matching

  1. The stub positions are fixed. Only the two stub lengths are varied, while a single stub needs both its position d and its length l to change.
  2. It suits adjustable tuners (sliding shorts in coax or waveguide) for loads that vary. A single stub would need a movable stub along a slotted line, which is impractical.
  3. It is easier to build in fixed microstrip or coax with a fixed junction. (Disadvantage: some loads cannot be matched, the forbidden region g > 1/sin²βd. A triple stub removes this.)

Steps for double-stub matching

  1. Normalise ZL, plot zL, and convert it to yL (rotate 180°).
  2. If the first stub is at d1 from the load, rotate yL toward the generator by d1 to get y1.
  3. Draw the g = 1 circle rotated toward the load by the stub spacing d (chart angle 720°·d/λ).
  4. From y1, move along its constant-g circle to the rotated g = 1 circle. This gives y1′ = g1 + jb′ and b1 = b′ − b(y1).
  5. Rotate y1′ toward the generator by d. It lands on the g = 1 circle: y2 = 1 + jb2′.
  6. Stub 2 must supply b2 = −b2′.
  7. Convert b1 and b2 into stub lengths (from the short-circuit point for shorted stubs, or the open-circuit point for open stubs).
  8. Check that y = 1 at stub 2.

Example

ZL = 60 − j80 Ω, Z0 = 50 Ω, short-circuited stubs, first stub at the load, spacing d = λ/8.

Step 1: Normalise and convert to admittance

zL = 1.200 − j1.600
yL = 1/zL = 0.300 + j0.400
ΓL = 0.593∠-46.8°,  VSWR = 3.911

On the chart, zL is at 0.3151λ WTG and yL is diametrically opposite, at 0.0651λ WTG.

Step 2: First stub at the load

The first stub is placed at the load, so y1 = yL = 0.300 + j0.400.

Step 3: Forbidden-region check and rotated g = 1 circle

βd = 360° × 0.125 = 45°
g must be ≤ 1/sin²βd = 2.000
g1 = 0.3000  → matchable

Rotate the g = 1 circle by 0.125λ (90° on the chart) toward the load. The point just after stub 1 must lie on this rotated circle, so move from y1 along the constant g = 0.300 circle until it meets the rotated circle.

Step 4: Susceptance of stub 1

Analytically (Pozar), with t = tan βd:

t = tan 45° = +1.0000
b1 = −B + [1 ± √((1+t²)g − g²t²)]/t
(1+t²)g − g²t² = 0.5100, √ = 0.7141
Sol A: b1 = +1.3141
Sol B: b1 = −0.1141

Step 5: Move 0.125λ to stub 2 and find b2

Sol A: y after stub 1 = 0.300 + j1.714
   (0.1675λ) → after 0.125λ: y2 = 1.000 − j3.380
   b2 = +3.3805
Sol B: y after stub 1 = 0.300 + j0.286
   (0.0481λ) → after 0.125λ: y2 = 1.000 + j1.380
   b2 = −1.3805

Both y2 values lie on the g = 1 circle, as required.

Step 6: Stub lengths

  • For a short-circuited stub: y = −j cot βl, so l = (1/2π)·cot⁻¹(−b). Measure toward the generator from the short-circuit point (y = ∞; with y plotted on an ordinary Smith chart, this is the right end, 0.25λ WTG).
Sol A short: l1 = 0.3965λ, l2 = 0.4542λ
Sol B short: l1 = 0.2319λ, l2 = 0.0998λ
QuantitySolution ASolution B
Stub 1 from loadat loadat load
Stub spacing0.125λ0.125λ
b1, b21.314, 3.380-0.114, -1.380
Short l1, l20.3965λ, 0.4542λ0.2319λ, 0.0998λ

Answer: solution B (l1 = 0.2319λ, l2 = 0.0998λ) gives the shorter total stub length.

 Z0=50Ω        λ/8
 o------+-------------+-------[60−j80 Ω]
        |             |
     stub 2        stub 1
     0.0998λ       0.2319λ
       SC            SC

✓ Answer checked by Claude Opus 5.5 (high effort)