Design network for two buildings with fiber

Short answer

Design using hierarchical model with core switch in server room, access switches per floor, VLANs for labs/staff/wireless, and single-mode fiber between buildings. Provide CAT6 cabling, PoE access switches, seven wireless APs, DHCP/DNS servers, and a router/firewall. Use private IP subnets with inter-VLAN routing on the core L3 switch.

What are the guidelines to design proper network system? You are asked to design a Network System for the organization which has 2 different buildings at less than 500 meter distance. The main building is 5-storey building which has Network/Server room in third floor. There are 3 computer training labs in 1st, 2nd and 3rd floor consisting of 20 computers at each lab. You need to provide internet to all lab computers as well as office computers for staffs. Connect two buildings from Fiber network. You can suggest multiple numbers of Wireless AP and/or Wired Network systems for your requirement. Prepare the required technical documents and suggest a network for the organization.

Guidelines for designing a proper network

  1. Find the requirements first: users, applications, traffic, growth for 3-5 years.
  2. Use a hierarchical model (core, distribution, access) so the network is easy to scale and troubleshoot.
  3. Follow structured cabling standards (TIA/EIA-568): CAT6 up to 90 m for permanent link, fibre for longer or between buildings.
  4. Plan redundancy and power backup (UPS) for critical links and servers.
  5. Plan IP addressing and VLANs; keep departments in separate subnets.
  6. Build in security (firewall, ACL, wireless encryption) and manageability (monitoring, labelling, documentation).
  7. Balance cost against performance, and leave spare ports and rack space.

Assumptions

  • Building A (main, 5 storeys) has the Network/Server room on the 3rd floor. Building B (annex) is about 450 m away, with 2 floors.
  • Labs: 3 labs x 20 PCs on floors 1, 2 and 3 of Building A = 60 PCs.
  • Staff offices: 30 PCs in Building A (6 per floor) and 20 PCs in Building B.
  • One Wi-Fi AP per floor in A (5) and 2 in B. One ISP link of 100 Mbps.
  • Floor height 3.5 m. Average horizontal cable run 30 m (A) and 25 m (B).

Topology

         Internet (ISP)
              |
       [Router + Firewall]
              |
   +----[Core L3 Switch]----+   3rd floor
   |      Servers: DHCP,    |   Server room
   |      DNS, Proxy, Web   |
   |                        |
 OM3 riser fibre        OS2 fibre ~500 m
   |                        |
 [SW-F1][SW-F2][SW-F4][SW-F5]  [SW-B]
 Lab1   Lab2   Staff  Staff    Bldg B
 +Staff +Staff +AP    +AP      Staff
 +AP    +AP                    +2 AP
 (SW-F3 sits in the server room itself)

Single-mode (OS2) armoured fibre with 1000BASE-LX SFP is laid in an underground HDPE duct between the buildings. Single-mode is chosen because it supports future 10G over the full distance.

IP plan (private range 192.168.0.0/16)

NetworkSubnetUsable hostsGatewayVLAN
Lab 1 (20 PCs)192.168.10.0/2730.110
Lab 2192.168.10.32/2730.3320
Lab 3192.168.10.64/2730.6530
Staff Building B192.168.10.96/2730.9740
Staff Building A (30 PCs)192.168.10.128/2662.12950
Wi-Fi (all APs)192.168.20.0/24254.160
Servers192.168.30.0/2730.170
Management192.168.99.0/2730.199

A /27 is enough for a 20-PC lab (20 PCs + gateway + spare). DHCP on the server gives addresses; servers and APs use static addresses. Inter-VLAN routing is done on the core L3 switch.

Bill of quantities

ItemSpecificationQty
UTP cableCAT6, 305 m box (about 3,400 m + 10% wastage)13 boxes
Information outletSingle-port faceplate with CAT6 jack (117 + spare)120
Patch panel24-port CAT6, rack mount9
Patch cordsCAT6, 2 m (user side)117
Patch cordsCAT6, 1 m (panel to switch)117
Core switchL3, 24 x GE + 4 x SFP+1
Access switch48-port PoE, 2 x SFP (floors 1-3)3
Access switch24-port PoE, 2 x SFP (floors 4, 5 and Building B)3
Wireless APDual-band, PoE7
Fibre OS26-core armoured, outdoor600 m
Fibre OM36-core indoor riser150 m
SFP modules1G LX (single-mode) / SX (multimode)4 / 8
Router + firewallWith NAT, ACL1
ServersDHCP, DNS, proxy/web2
Racks42U (server room), 9U wall mount (floors)1 / 5
UPS3 kVA online (server room), 1 kVA (floors)1 / 5
MiscConduit, trunking, labels, testerlot

Technical documents to prepare

  • Requirement and scope document, assumptions.
  • Logical and physical network diagram (as above), floor plans with outlet positions.
  • IP addressing and VLAN plan, DHCP scope sheet.
  • Cable schedule and labelling scheme, fibre test results.
  • Bill of quantities with cost estimate.
  • Configuration backup, security policy, user manual, and as-built drawing after installation.