- 2068 Chaitra · 8 marks
Correct length of 1350 m line
Short answer
Assuming standard length 29.985 m, apply tape length correction (-0.6750 m), temperature (-0.0446 m), pull (+0.0265 m), and sag correction for 45 spans (-0.5416 m). Correct length: 1348.765 m.
A 30 m steel tape standardized in fully supported condition at a temperature of 20°C and pull of 100 N was found to be 19.985 m. This tape was used to measure a line under a pull of 120 N and a mean temperature of 17°C and was found to be 1350 m long. Throughout the measurement, the tape was used in catenary condition. Find the correct length of the line. Take weight of steel as 0.081 N/cm³, the weight of tape as 11.775 N, N/mm² and /°C.
Reading of the data. The tape is stated as "30 m" but the standard length is printed "19.985 m". This is taken as 29.985 m (a 30 m tape 0.015 m short). The tape is fully supported at standardisation and used in catenary in 30 m spans, so 1350 m tapes.
Data
- N for 30 m, N/m; density of steel N/cm
- cm mm
- N/mm, so N
- Standard: 29.985 m at C and N; field: C, N, m
- /C
1. Tape length
2. Temperature
3. Pull
4. Sag
Per tape: m; m.
5. Correct length
Answer: correct length of the line m (with the standard length read as 29.985 m).
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- True length: tape found 2.5 cm too long · Surveying I, chapter 2
- True length of 1020 m line, 20 m tape · Surveying I, chapter 2 · asked 2×
- Correct base line length 1120 m · Surveying I, chapter 2
- True length of 680 m line, 20 m tape · Surveying I, chapter 2 · asked 3×
- Correction per tape length (kgf data, 61) · Surveying I, chapter 2 · asked 2×
- True length of 780 m line, tape 0.693 kg · Surveying I, chapter 2 · asked 2×
- Subnet 120.89.96.0/19 for 100-800 hosts · Computer Networks and Security, chapter 4 · asked 2×
- Initial line design for 200 MW over 120 km · Transmission and Distribution System Design, chapter 2
- Subnet 202.77.19.0/24 for 30, 24, 25, 20 · Computer Networks and Security, chapter 4
- Two machines 100∠0° and 120∠30° V via j5 Ω · Power System Analysis I, chapter 3