- 2077 Chaitra · 8 marks
Commutator, brushes; start shunt generator no load
Short answer
The commutator mechanically rectifies AC armature emf to DC and collects current. Carbon brushes make sliding contact, are self-lubricating, and reduce sparking. Shunt generator must start on open circuit: a load diverts the small initial armature current from the field, and armature reaction weakens residual flux, preventing voltage buildup.
Explain the functions of commutator and carbon brushes in d.c. generator. Explain why dc shunt generator should be started without load.
Function of the commutator
- It acts as a mechanical rectifier: it converts the alternating emf induced in the armature conductors into a unidirectional (DC) voltage at the brushes.
- It collects the current from the armature conductors and passes it to the brushes.
- It connects the correct coil to the brush at the correct time. The copper segments are separated by mica insulation.
Function of the carbon brushes
- They make sliding contact with the commutator and carry the armature current to the external load.
- Carbon is self-lubricating and causes little wear on the commutator, and its high contact resistance reduces sparking.
- They are placed at the magnetic neutral axis for sparkless commutation.
Why a shunt generator is started without load
A shunt generator is self-excited. The emf builds up from the residual magnetism like this: residual emf small field current more flux more emf, until the field-resistance line meets the magnetisation curve.
If the load is connected during starting:
- The terminal voltage is very low, so a large part of the armature current goes to the load and the field current is reduced (), because the load is in parallel with the field.
- The voltage drop in the armature takes away a larger share of the small emf, so the terminal voltage stays near zero.
- The armature reaction of the load current weakens the small flux further, so the machine may fail to build up its voltage at all.
Hence the load is connected only after the voltage has reached its rated value.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- DC series motor should not start on no-load · Electrical Machines, chapter 4
- DC motor principle and role of commutator and brushes · Electrical Machines I, chapter 4
- DC series motor started at no load: true/false · Electrical Machines, chapter 4
- Starting shunt generator on no load and voltage build-up · Electrical Machines I, chapter 3
- Function of commutator in DC generator · Electrical Machines I, chapter 3
- Series motor load start; shunt motor speed control · Electrical Machines, chapter 4
- Commutator and carbon brush functions · Electrical Machine, chapter 3
- True/false: series motor started at no load · Electrical Machine, chapter 4
- Shunt generator started with output open · Electrical Machine, chapter 3
- DC generator principle; brush functions · Electrical Machine, chapter 3