- 2066 Magh (old course) · 8 marks
6-pole motor: rotor loss and efficiency
Short answer
Synchronous speed 1000 rpm, slip 0.05. Air-gap power = 50 kW – 1.5 kW = 48.5 kW. Rotor loss = slip × Pg = 2.425 kW. Out put = Pg – rot or loss – 2 kW friction = 44.075 kW; efficiency = 88.15 %.
A 3-phase, 440 V, 50 Hz, 6-pole induction motor draws 50 kW at 0.85 lagging p.f. from the source when connected to rated supply. If rotor rotates at 950 rpm, calculate (i) rotor loss and (ii) overall efficiency of the motor. The friction loss and stator loss are 2 kW and 1.5 kW respectively at this running condition.
Given: 440 V, 50 Hz, 6-pole, input kW at 0.85 lagging p.f., rpm, friction loss kW, stator loss kW.
Power flow
Air-gap power (rotor input):
(i) Rotor loss
(ii) Efficiency
Mechanical power developed: kW Output: kW
(The power factor is not needed.)
Answer: (i) rotor copper loss kW; (ii) efficiency .
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Rotor copper loss and efficiency of 35 kW induction motor · Electrical Machines I, chapter 5
- Rotor copper loss, frequency, current and efficiency of 11 kW motor · Electrical Machines I, chapter 5
- Full-load torque, rotor current and copper loss of 440 V motor · Electrical Machines I, chapter 5
- Slip, rotor copper loss, shaft power and efficiency at 975 rpm · Electrical Machines I, chapter 5
- 6-pole induction motor: slip, losses, efficiency · Electrical Machines, chapter 5
- Torque of 4-pole induction motor at 1400 rpm · Electrical Machines I, chapter 5
- 440 V IM with 50 kW rotor input · Electrical Machine, chapter 5
- 2.2 kW 440 V cage motor (star-delta) design · Electric Machine Design, chapter 4 · asked 3×
- Air gap and rotor bars, 10 kW motor · Electric Machine Design, chapter 4
- Delta capacitor per phase for 50 kW motor · Basic Electrical Engineering, chapter 8