T-S characteristics and effect of rotor resistance
Short answer
Torque-slip curve rises linearly in low-slip stable region, peaks at sm = R2/X2, then falls. Starting torque occurs at s=1; maximum torque is independent of rotor resistance. Increasing rotor resistance shifts peak toward s=1 and increases starting torque up to Tmax.
Explain the torque-slip characteristics of a 3-phase induction motor, indicating the starting torque, maximum torque and the operating region. How does rotor resistance affect the torque-slip characteristics?
The torque-slip characteristic shows how the torque developed by a 3-phase induction motor varies with slip (from at standstill to at synchronous speed), at rated voltage and frequency.
Torque of a 3-phase induction motor at slip (per-phase equivalent):
where and are the rotor emf and reactance per phase at standstill and is the synchronous speed in rad/s.
Torque T
| Tmax
| .--*--.
| Tst / | \ Operating
| *--' | \ region
| | \___ ___ (stable)
| |
+------------+-----------+----> slip s
1 (standstill) sm 0 (sync)
Regions of the curve
- Starting point (): the torque is the starting torque . Here the rotor reactance is large, so the rotor power factor is low and the torque is less than the maximum.
- Low-slip (operating) region (): the rotor reactance is small, so and . The curve is almost a straight line. The motor works stably here: if the load rises, the speed falls slightly, slip increases and torque increases to meet it. The full-load slip is only about 2–5%.
- Maximum torque point (): the pull-out or breakdown torque occurs at and has the value
- High-slip region (): torque decreases as slip increases because dominates (). This region is unstable for normal loads; if the load torque exceeds , the motor stalls.
Effect of rotor resistance
does not depend on , but the slip at which it occurs does: .
T
| R2 low R2 med R2 high
| .-*-. .-*-. .-*-.
| / \ / \ / \
| / \ / \ / \
+---+--------+---------+--+--------+--> s
- Increasing (wound-rotor motor with external resistance) moves the peak toward higher slip (toward ). When , and maximum torque occurs at starting.
- The starting torque increases (up to when ; more resistance beyond that reduces it again) and the starting current falls (better rotor power factor).
- The slope in the operating region becomes less steep, so the speed regulation worsens (more slip for the same torque), and the running efficiency falls due to loss.
- Hence external rotor resistance is used for starting and speed control in slip-ring motors, and then cut out for running.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Torque-slip curve: starting, maximum and operating region · Electrical Machines I, chapter 5
- Torque-slip characteristic and effect of rotor resistance · Electrical Machines I, chapter 5 · asked 6×
- T-S characteristics, max torque, rotor resistance effect · Electrical Machines, chapter 5
- Effect of five-times rotor resistance on 40 kW slip ring motor · Electrical Machines I, chapter 5
- Starting current and rotor resistance for 150 kW slip ring motor · Electrical Machines I, chapter 5
- Maximum torque and torque at 1430 rpm of slip ring motor · Electrical Machines I, chapter 5 · asked 3×
- Torque-slip curve and rotor resistance · Electrical Machine, chapter 5 · asked 3×
- Torque-slip curve; linear operating region · Electrical Machine, chapter 5
- Single phase IM principle, torque-slip and starting · Electric Machines II, chapter 3
- Max torque independent of rotor resistance · Electrical Machine, chapter 5