- Asked 6/22
- 2077 Chaitra · 8 marks
- 2076 Bhadra · 8 marks
- 2075 Bhadra · 8 marks
- 2073 Magh · 8 marks
- 2071 Bhadra · 8 marks
- 2070 Magh · 8 marks
Torque-slip characteristic and effect of rotor resistance
Short answer
The torque–slip characteristic has a stable low-slip region where T ∝ s, a peak at slip sm = R2/X2, and an unstable high-slip region. Increasing rotor resistance shifts the peak to higher slip without changing maximum torque, raising starting torque (up to R2 = X2) but increasing full-load slip and losses.
Explain the torque-slip characteristics of a 3-phase induction motor and explain the effect of rotor circuit resistance on the characteristic.
The torque–slip characteristic of a 3-phase induction motor is the curve of developed torque against slip (or speed) at constant supply voltage and frequency.
Torque equation
where and are rotor emf and reactance per phase at standstill, is rotor resistance, is slip and with in rps.
Shape of the curve
T
| Tmax
| .--.
| .' '.
| / '.
| / '-.
| / '-. Tst
| / stable | unstable
| / |
| / |
|/_____________|____________ s
0 sm 1
(N=Ns) (N=0)
- Low-slip region (, normal running): , so , i.e. . The curve is nearly a straight line through the origin. This is the stable operating region; speed falls only slightly as load rises.
- Maximum torque: occurs at , with . It is also called pull-out or breakdown torque.
- High-slip region (): , so , i.e. . The curve is a rectangular hyperbola. Operation here is unstable: if load increases, speed falls, torque falls further, and the motor stalls.
- At the torque is the starting torque .
Effect of rotor circuit resistance
When is increased, the whole curve keeps the same peak height but the peak moves to the right (towards ).
Using with , for :
| (Ω) | ||
|---|---|---|
| 0.1 | 0.1 | 0.198 |
| 0.3 | 0.3 | 0.550 |
| 0.5 | 0.5 | 0.800 |
| 1.0 | 1.0 | 1.000 |
- Maximum torque is unchanged: does not contain .
- Slip at maximum torque increases: , so higher shifts the peak towards (lower speed).
- Starting torque increases up to , when and . Beyond that, starting torque falls again.
- Starting current decreases and starting power factor improves.
- Full-load slip increases, so running efficiency falls (rotor copper loss ) and speed regulation becomes poorer.
This is why slip-ring motors use external rotor resistance only during starting (or for speed control) and short it out in normal running. Double-cage and deep-bar motors get the same effect automatically.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Induction motor torque equation and torque-slip characteristic · Electrical Machines I, chapter 5
- Effect of five-times rotor resistance on 40 kW slip ring motor · Electrical Machines I, chapter 5
- Starting current and rotor resistance for 150 kW slip ring motor · Electrical Machines I, chapter 5
- Induction motor equivalent circuit from no-load and blocked rotor tests · Electrical Machines I, chapter 5
- Slip ring motor max-torque slip and full-load output · Electrical Machines I, chapter 5 · asked 4×
- Maximum torque and torque at 1430 rpm of slip ring motor · Electrical Machines I, chapter 5 · asked 3×
- T-S characteristics, max torque, rotor resistance effect · Electrical Machines, chapter 5
- Torque-slip curve and rotor resistance · Electrical Machine, chapter 5 · asked 3×
- Effect of rotor resistance on T-S characteristics · Electrical Machines, chapter 5
- T-S characteristics and effect of rotor resistance · Electrical Machines, chapter 5 · asked 2×