Skip to main content

Pipe diameter to halve pumping cost

Short answer

Pumping power is proportional to head loss, which varies as D^(−16/3) for rough turbulent flow with f ∝ D^(−1/3). Halving the cost requires D' ≈ 569 mm. Using n parallel pipes at the same Re increases running cost by a factor of n^(10/3).

Petrol of kinematic viscosity 0.6 mm²/s is to be pumped at the rate of 0.8 m³/s through a horizontal pipe 500 mm diameter. However, to reduce pumping costs a pipe of different diameter is suggested. Assuming that the absolute roughness of the walls would be the same for a pipe of slightly different diameter, and that, for Re > 10610^6, f is approximately proportional to the cube root of the roughness, determine the diameter of pipe for which the pumping costs would be halved. Neglect all head losses other than pipe friction. How are the running costs altered if n pipes of equal diameter are used in parallel to give the same total flow rate at the same Reynolds number as for a single pipe?

Data. ν=0.6×10−6\nu = 0.6\times10^{-6} m²/s, Q=0.8Q = 0.8 m³/s, D=0.5D = 0.5 m, same absolute roughness kk for the new pipe.

V=4QπD2=4.074 m/s,Re=VDν=3395305>106V = \frac{4Q}{\pi D^2} = 4.074\ \text{m/s},\qquad Re = \frac{VD}{\nu} = 3395305 > 10^6

So f∝(k/D)1/3f \propto (k/D)^{1/3} may be used.

Part 1: Diameter for half the pumping cost

Pumping cost is proportional to the power P=ρgQhfP = \rho g Q h_f. With QQ fixed, cost ∝hf\propto h_f (neglecting all losses except friction).

hf=fLV22gD,V=4QπD2  ⇒  hf∝fD5h_f = \frac{fLV^2}{2gD}, \qquad V = \frac{4Q}{\pi D^2} \;\Rightarrow\; h_f \propto \frac{f}{D^5}

For constant kk: f∝(kD)1/3∝D−1/3f \propto \left(\dfrac{k}{D}\right)^{1/3} \propto D^{-1/3}, so

hf∝D−1/3 D−5=D−16/3h_f \propto D^{-1/3}\,D^{-5} = D^{-16/3}

Cost halved: (D′D)−16/3=12\left(\dfrac{D'}{D}\right)^{-16/3} = \dfrac{1}{2} gives

D′D=23/16=1.1388  ⇒  D′=0.5(1.1388)=0.569 m≈569 mm\frac{D'}{D} = 2^{3/16} = 1.1388 \;\Rightarrow\; D' = 0.5(1.1388) = 0.569\ \text{m} \approx 569\ \text{mm}

Check: new velocity V′=3.142V' = 3.142 m/s and Re′=2981506>106Re' = 2981506 > 10^6, so the assumption holds.

Part 2: n equal pipes in parallel at the same Reynolds number

The same Re=VD/νRe = VD/\nu for the same fluid means V′D′=VDV'D' = VD. Each of the nn pipes carries Q/nQ/n:

Qn=π4D′2V′  ⇒  π4D2V=nπ4D′2V′=nπ4D′ (VD)  ⇒  D′=Dn,V′=nV\frac{Q}{n} = \frac{\pi}{4}D'^2V' \;\Rightarrow\; \frac{\pi}{4}D^2V = n\frac{\pi}{4}D'^2V' = n\frac{\pi}{4}D'\,(VD)\;\Rightarrow\; D' = \frac{D}{n},\quad V' = nV

Relative roughness rises to k/D′=n(k/D)k/D' = n(k/D), so f′=n1/3ff' = n^{1/3}f. Head loss of each pipe (all pipes have the same hfh_f in parallel):

hf′=f′LV′22gD′=n1/3f L n2V22g(D/n)=n3+1/3hf=n10/3hfh_f' = \frac{f'LV'^2}{2gD'} = \frac{n^{1/3}f\,L\,n^2V^2}{2g(D/n)} = n^{3+1/3}h_f = n^{10/3}h_f

The discharge is the same, so the power and the running cost increase by the factor

cost′cost=n10/3\boxed{\frac{\text{cost}'}{\text{cost}} = n^{10/3}}

For example, two pipes (n=2n = 2) cost 210/3=10.12^{10/3} = 10.1 times as much. Using one large pipe is much cheaper than several small ones.

Answer: D′≈569D' \approx 569 mm (about 570 mm); running cost rises by n10/3n^{10/3} for nn parallel pipes.

✓ Answer checked by Claude Sonnet 5.5

All Hydraulics chapter 1 questions →