- 2076 Baisakh · 8 marks
Flow rate 2 s after pump failure
Short answer
After instantaneous pump stop, the water column decelerates under static head and friction. Using rigid-column theory, the flow rate at t=2 s is 29.3 L/s.
A pump draws water from a reservoir and delivers it at a steady rate of 115 L/s to a tank in which the free surface level is 12 m higher than that in the reservoir. The pipe system consists of 30 m of 225 mm diameter pipe (f = 0.028) and 100 m of 150 mm diameter pipe (f = 0.032) arranged in series. Determine the flow rate 2 s after a failure of the power supply to the pump, assuming that the pump stops instantaneously. Neglect minor losses in the pipes and in the pump, and assume an incompressible fluid in rigid pipes with f independent of Reynolds number.
Data. Static lift m. Pipe 1: m, m, . Pipe 2: m, m, . Steady flow l/s. After the pump stops instantaneously, the water column keeps moving for a short time, decelerating under the static head and friction. Treat the water as incompressible and the pipes as rigid (rigid-column theory).
Constants
- Areas: m², m².
- Inertia term:
- Friction coefficients, with : , , so s²/m⁵ (check: the steady friction head at 115 l/s is m).
Equation of motion
After the pump fails, two effects decelerate the whole water column: the static head (pushing the water back) and friction (opposing the forward motion). For the pipes in series:
Separate the variables and integrate from :
Numbers
At s:
(The flow stops completely at s.)
Answer: The flow rate 2 s after the power failure is about l/s (still forward), down from 115 l/s.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Duration of flow after pump stops · Hydraulics, chapter 4
- Pump power and pipe length with Colebrook · Hydraulics, chapter 2
- Three reservoirs with pump in pipe 2 · Hydraulics, chapter 3
- Flow rate from drop in surface over hump · Hydraulics, chapter 7
- Branching pipe system and three-reservoir cases · Hydraulics, chapter 3
- Flow between reservoirs (20 cm and 30 cm pipe) · Hydro Power, chapter 1
- Reservoir level change, water balance, 1600 ha · Engineering Hydrology, chapter 1 · asked 2×
- Reservoir level change, water balance, 15.5 km2 · Engineering Hydrology, chapter 1 · asked 2×
- Pipe outlet minimum water level, 50 lps · Irrigation and Drainage Engineering, chapter 7