Pump power and pipe length with Colebrook
Short answer
Pipe length is 124 m using f=0.0203 from Colebrook. If head loss doubles, discharge reduces to 204 L/s, about an 18% drop because friction loss falls with the square of flow.
If a flow of 0.25 m³/s of water is to be maintained in the system shown below, the power required by the pump to maintain the water levels is 54642 watts. The pipe is made of iron (e = 0.26 mm) and is 250 mm in diameter. Take = 0.0021 N·s/m². Take all losses and use Colebrook-White equation, if needed. (i) Find the length of the pipe. (ii) For the same power if the loss of head is doubled, find the discharge. Write your comment on the result. [Figure: two reservoirs with water surface elevations 12 m (left) and 19 m (right) connected by a pipe of length L with a pump in the line]
Data. m³/s, pump power W, m, mm, N s/m², water kg/m³. Reservoir levels 12 m and 19 m, so the static lift is m. All losses are considered: entrance , exit and friction.
(i) Length of the pipe
Pump head:
Energy equation between the reservoir surfaces: , so the head loss is m.
Velocity and Reynolds number:
Relative roughness . Colebrook-White (solved by iteration):
Head loss:
(ii) Same power, loss of head doubled
"Loss of head doubled" means that, at the same flow, the system now loses twice as much head (for example a longer or rougher pipe). The head loss varies as , so for the original pipe
and for the new system (taking as constant, since it changes very little). The pump head is then
For the same power :
Solving by trial: gives 5.31, gives 5.65, and gives 5.58. So
At this flow the head loss is m and the pump head is m. (Allowing to vary with in the Colebrook-White equation gives 203.6 l/s, practically the same.)
Comment. Doubling the loss cuts the discharge from 250 l/s to about 204 l/s, a fall of about 18%, for the same power. The 7 m static lift is a fixed requirement, but the pump must also supply the friction head. When friction rises, more of the same power is spent overcoming it and less water is delivered. The discharge falls by much less than the loss rises, because the head loss falls with the square of the flow. It would be wrong to keep the doubled loss of 30.56 m at the old flow and divide the power by . That gives 148 l/s, which is too low, because the friction loss itself drops as the flow drops.
Answer: (i) m (); (ii) l/s.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Siphon with 90 mm pipe, number and length · Hydraulics, chapter 2
- Three reservoirs with pump in pipe 2 · Hydraulics, chapter 3
- Pump-driven circulating pipe network · Hydraulics, chapter 3
- Flow rate 2 s after pump failure · Hydraulics, chapter 4
- Duration of flow after pump stops · Hydraulics, chapter 4
- Three reservoirs with 250 mm concrete pipes · Hydraulics, chapter 3 · asked 2×
- Water hammer in elastic cast-iron pipe · Hydro Power, chapter 1
- Flow between reservoirs (15 cm and 25 cm pipe) · Hydro Power, chapter 1
- Friction pile length, 300 mm, 250 kN · Foundation Engineering, chapter 8
- Hardness of well water with strontium 25.26 mg/l · Water Supply Engineering, chapter 4