Main dimensions and poles of 40 kW shunt motor

Short answer

Pa=(2+η)/(3η)×P=42.32 kW, Co=108.6, D²L=0.01613 m³. For square pole face, trying p=4 gives D=0.308 m, L=0.170 m, frequency 48.3 Hz (acceptable); p=6 exceeds 50 Hz, p=2 gives L>D. Hence 4 poles, D=0.308 m, L=0.170 m.

Calculate the main dimensions and the number of poles of a 40 kW, 240 V, 1450 rpm dc shunt motor so that a square pole face is obtained. The average gap density is 0.5 Wb/m² and ampere conductors per meter are 22000. Take full load efficiency of 92% and ratio of pole arc to pole pitch of 0.7.

The main dimensions come from the output equation of a dc machine (A.K. Sawhney):

Pa=C0D2Ln,C0=π2Bav ac×10−3 kW/(m3 rps)P_a = C_0 D^2 L n, \qquad C_0 = \pi^2 B_{av}\, ac \times 10^{-3}\ \text{kW/(m}^3\text{ rps)}

where PaP_a = armature power (kW), DD = armature diameter, LL = core length (m), nn = speed (rps).

For a motor, Sawhney takes the armature copper loss as about one-third of the total losses, which gives

Pa=2+η3η PP_a = \frac{2+\eta}{3\eta}\,P

Step 1: Armature power and D2LD^2L

Pa=2+0.923×0.92×40=42.32 kWC0=π2×0.5×22000×10−3=108.6n=1450/60=24.17 rpsD2L=42.32108.6×24.17=0.01613 m3\begin{aligned} P_a &= \frac{2+0.92}{3\times0.92}\times40 = 42.32\ \text{kW} \\ C_0 &= \pi^2 \times 0.5 \times 22000\times10^{-3} = 108.6 \\ n &= 1450/60 = 24.17\ \text{rps} \\ D^2L &= \frac{42.32}{108.6\times24.17} = 0.01613\ \text{m}^3 \end{aligned}

Step 2: Square pole face

Core length = pole arc: L=ψπD/p=0.7πD/pL = \psi\pi D/p = 0.7\pi D/p, so

D3=D2L  p0.7πD^3 = \frac{D^2L\; p}{0.7\pi}

Step 3: Choice of number of poles

Try common pole numbers and check frequency (f=pn/2≤50f = pn/2 \le 50 Hz) and peripheral speed (≤30\le 30 m/s):

Poles ppDD (m)LL (m)πDn\pi Dn (m/s)ff (Hz)
20.2450.26918.624.2
40.3080.17023.448.3
60.3530.12926.872.5
  • p=6p = 6 gives f=72.5f = 72.5 Hz, too high (large iron loss).
  • p=2p = 2 gives a long, narrow machine (L>DL > D) with heavy armature reaction per pole and large yoke; not used for 40 kW.
  • p=4p = 4 keeps ff below 50 Hz with a reasonable L/DL/D. Armature current ≈40000/(0.92×240)=181\approx 40000/(0.92\times240) = 181 A, so with a lap winding the current per path (≈45\approx 45 A) and current per brush arm (≈90\approx 90 A) are small.

Choose 4 poles.

Step 4: Main dimensions for p=4p = 4

D3=0.01613×40.7π=0.02934 m3D=0.308 mL=0.7π×0.3084=0.170 mτ=πDp=0.242 m,pole arc=0.7τ=0.170 m\begin{aligned} D^3 &= \frac{0.01613\times4}{0.7\pi} = 0.02934\ \text{m}^3 \\ D &= 0.308\ \text{m} \\ L &= \frac{0.7\pi\times0.308}{4} = 0.170\ \text{m} \\ \tau &= \frac{\pi D}{p} = 0.242\ \text{m}, \quad \text{pole arc} = 0.7\tau = 0.170\ \text{m} \end{aligned}

Answer: Number of poles = 4, armature diameter D≈0.308D \approx 0.308 m, core length L≈0.170L \approx 0.170 m (pole face 0.170 m x 0.170 m).

✓ Answer checked by Claude Sonnet 5.5