Choice of number of poles in DC machine
Short answer
Choice balances frequency (25–50 Hz), iron and copper weight, armature reaction per pole, current per brush arm (≤200 A), flashover voltage between segments (<20 V), and labour/cost. More poles lower material and armature reaction but raise frequency and manufacturing effort.
Explain the factors to be considered while selecting the number of poles in a dc machine.
The number of poles of a dc machine is chosen after the output equation gives . More poles reduce some material but increase other costs and losses, so a compromise is made.
1. Frequency of flux reversal
The armature iron sees alternating flux at this frequency. Iron loss rises with , so is normally kept between 25 and 50 Hz. This limits the number of poles at high speed.
2. Weight of iron
For the same total flux, the flux per pole . So the yoke and armature core depth (which carry ) become thinner, and the iron weight falls as increases.
3. Weight of copper
- Armature copper: the end connections are shorter for a smaller pole pitch, so armature copper decreases with more poles.
- Field copper: each pole needs its own coil. The total field copper stays roughly constant or falls a little.
4. Armature reaction (ampere-turns per pole)
More poles lower the armature mmf per pole, so the distortion and the field mmf needed to overcome armature reaction are less. A typical limit is armature AT per pole below about 5000–10000, depending on output.
5. Current per brush arm / per path
For a lap winding, the current per path . It should not exceed about 200 A (and about 400 A per brush arm), otherwise the commutator becomes long and commutation becomes difficult. Large-current machines therefore need more poles.
6. Commutator length and brushes
More poles mean more brush arms with a smaller current in each, so the commutator is shorter, but there is more brush gear.
7. Overall size, labour and cost
More poles give a smaller overall diameter and less material, but they need more coils, more parts and more labour. Frequency and losses also rise.
8. Voltage between commutator segments (flashover)
For a lap winding, the terminal voltage is spread over segments in series, so the average voltage between adjacent segments is . This must be kept below about 20 V to avoid flashover. For the same terminal voltage, more poles therefore need more commutator segments, which makes the commutator larger and more costly.
Typical choice
| Output | Usual poles |
|---|---|
| Up to about 5 kW | 2 |
| 5–100 kW | 4 |
| 100–500 kW | 6 to 8 |
| Above 500 kW | 8 or more |
Example: a 37 kW, 1400 rpm motor with 4 poles has Hz and a current per path of about 45 A, so 4 poles is suitable. Six poles would give 70 Hz, which is too high.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Field form factor and choice of poles · Electric Machine Design, chapter 5 · asked 8×
- Choice of ampere conductors per meter in DC machine · Electric Machine Design, chapter 5 · asked 4×
- Choice of specific loadings in DC machine · Electric Machine Design, chapter 5 · asked 2×
- Choice of number of armature slots · Electric Machine Design, chapter 5
- Choice of specific electric loading in induction machine · Electric Machine Design, chapter 4 · asked 3×
- Choice of magnetic loading in induction machine · Electric Machine Design, chapter 4
- Output equation of DC machine · Electric Machine Design, chapter 5 · asked 3×
- Factors for selecting construction materials · Civil Engineering Materials, chapter 1 · asked 9×
- Factors in selecting construction equipment · Construction Management, chapter 4 · asked 6×
- Factors for selecting roof covering · Building Technology, chapter 4 · asked 2×
- Selecting main stations; number of offsets · Surveying I, chapter 3