Choice of number of poles in DC machine

Short answer

Choice balances frequency (25–50 Hz), iron and copper weight, armature reaction per pole, current per brush arm (≤200 A), flashover voltage between segments (<20 V), and labour/cost. More poles lower material and armature reaction but raise frequency and manufacturing effort.

Explain the factors to be considered while selecting the number of poles in a dc machine.

The number of poles of a dc machine is chosen after the output equation gives D2LD^2L. More poles reduce some material but increase other costs and losses, so a compromise is made.

1. Frequency of flux reversal

f=Pn2f = \frac{Pn}{2}

The armature iron sees alternating flux at this frequency. Iron loss rises with ff, so ff is normally kept between 25 and 50 Hz. This limits the number of poles at high speed.

2. Weight of iron

For the same total flux, the flux per pole Φ∝1/P\Phi \propto 1/P. So the yoke and armature core depth (which carry Φ/2\Phi/2) become thinner, and the iron weight falls as PP increases.

3. Weight of copper

  • Armature copper: the end connections are shorter for a smaller pole pitch, so armature copper decreases with more poles.
  • Field copper: each pole needs its own coil. The total field copper stays roughly constant or falls a little.

4. Armature reaction (ampere-turns per pole)

ATa=ac πD2PAT_a = \frac{ac\,\pi D}{2P}

More poles lower the armature mmf per pole, so the distortion and the field mmf needed to overcome armature reaction are less. A typical limit is armature AT per pole below about 5000–10000, depending on output.

5. Current per brush arm / per path

For a lap winding, the current per path =Ia/P= I_a/P. It should not exceed about 200 A (and about 400 A per brush arm), otherwise the commutator becomes long and commutation becomes difficult. Large-current machines therefore need more poles.

6. Commutator length and brushes

More poles mean more brush arms with a smaller current in each, so the commutator is shorter, but there is more brush gear.

7. Overall size, labour and cost

More poles give a smaller overall diameter and less material, but they need more coils, more parts and more labour. Frequency and losses also rise.

8. Voltage between commutator segments (flashover)

For a lap winding, the terminal voltage VV is spread over Nseg/PN_{seg}/P segments in series, so the average voltage between adjacent segments is es=VP/Nsege_s = VP/N_{seg}. This must be kept below about 20 V to avoid flashover. For the same terminal voltage, more poles therefore need more commutator segments, which makes the commutator larger and more costly.

Typical choice

OutputUsual poles
Up to about 5 kW2
5–100 kW4
100–500 kW6 to 8
Above 500 kW8 or more

Example: a 37 kW, 1400 rpm motor with 4 poles has f=4×1400/120=46.7f = 4 \times 1400/120 = 46.7 Hz and a current per path of about 45 A, so 4 poles is suitable. Six poles would give 70 Hz, which is too high.

✓ Answer checked by Claude Sonnet 5.5

All Electric Machine Design chapter 5 questions →