Choice of specific loadings in DC machine
Short answer
Specific magnetic loading (B_av) is limited by tooth saturation, iron loss (increases with frequency and square of flux density), field mmf, and armature reaction. Specific electric loading (ac) is limited by temperature rise, speed, insulation requirements, armature reaction, commutation (reactance voltage), and copper loss. They are chosen together to balance iron and copper.
Explain various factors that should be considered while selecting the value of specific electrical and magnetic loading in dc machine.
The output coefficient shows that high specific loadings give a small machine. Their upper limits are set by the factors below.
Specific magnetic loading (), usually 0.4–0.8 Wb/m²
- Flux density in teeth: the teeth carry the gap flux through a smaller area. Tooth density should not exceed about 2.1–2.2 Wb/m² in dc machines; otherwise the teeth saturate and need a large field mmf.
- Frequency of flux reversal: iron loss grows with frequency and . High-speed or many-pole machines (high ) need a lower .
- Iron loss and efficiency: higher raises iron loss, lowers efficiency and raises temperature.
- Size of machine: higher means smaller and lower cost.
- Field mmf: higher gap density needs more field ampere-turns, so more field copper and larger poles.
- Armature reaction: a higher (stronger main field) keeps the armature mmf relatively smaller, which helps against distortion.
Specific electric loading (), usually 15000–50000 A/m
- Temperature rise: more copper loss per unit surface; good ventilation allows a higher value.
- Speed: fast machines cool better and can take a higher .
- Voltage: thicker insulation at high voltage leaves less room for copper, so a lower .
- Size of machine: large machines can take higher .
- Armature reaction: armature AT per pole ; high means strong armature reaction.
- Commutation: high gives high reactance voltage and poor commutation.
- Copper loss and efficiency: increase with .
Summary
| Factor | Limits | Limits |
|---|---|---|
| Teeth saturation | Yes | No |
| Iron loss, frequency | Yes | No |
| Copper loss, heating | Little | Yes |
| Armature reaction | Helps if high | Worse if high |
| Commutation | Little | Yes |
| Voltage (insulation) | No | Yes |
The ratio also fixes the ratio of iron to copper in the machine, so the two are chosen together.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Choice of specific electric loading in induction machine · Electric Machine Design, chapter 4 · asked 3×
- Disadvantages of high specific loadings in DC machine · Electric Machine Design, chapter 5 · asked 2×
- Choice of magnetic loading in induction machine · Electric Machine Design, chapter 4
- Choice of number of poles in DC machine · Electric Machine Design, chapter 5 · asked 8×
- Choice of ampere conductors per meter in DC machine · Electric Machine Design, chapter 5 · asked 4×
- True/False: magnetic loading and teeth flux density · Electric Machine Design, chapter 5
- Factors for selecting roof covering · Building Technology, chapter 4 · asked 2×
- Factors for selecting a motor · Utilization of Electrical Energy, chapter 2 · asked 2×
- Factors for selecting construction materials · Civil Engineering Materials, chapter 1 · asked 9×
- Factors in selecting construction equipment · Construction Management, chapter 4 · asked 6×