Disadvantages of high specific loadings in DC machine

Short answer

Higher B_av increases iron loss, may saturate teeth, demands larger field mmf and more field copper. Higher ac raises copper loss, temperature rise, armature reaction, and reactance voltage, worsening commutation and possibly requiring interpoles. Both reduce efficiency and can increase overall size.

What are the disadvantages of higher specific electric and magnetic loading in design of DC machine?

High specific loadings reduce the size and cost of a dc machine (since D2L=Pa/(π2Bav ac n×10−3)D^2L = P_a/(\pi^2B_{av}\,ac\,n\times10^{-3})), but they have the following disadvantages.

Higher specific magnetic loading (BavB_{av})

  • Higher iron loss: core loss rises roughly with B2B^2, so efficiency falls and temperature rises.
  • Teeth saturation: flux density in the teeth may exceed about 2.2 Wb/m², needing a very large field mmf.
  • More field copper: more ampere-turns are needed for the gap and teeth, so field copper loss, field coil size and pole size increase.
  • Larger poles and yoke: the flux per pole is larger, so the poles and yoke must be bigger, and the overall diameter may increase.

Higher specific electric loading (acac)

  • Higher copper loss and lower efficiency.
  • Higher temperature rise: more heat per unit surface of armature; may need forced cooling.
  • Stronger armature reaction: armature AT per pole =ac πD/2P= ac\,\pi D/2P increases, causing more field distortion, loss of flux and need of compensating winding.
  • Poorer commutation: reactance voltage increases, causing sparking; interpoles may be needed.
  • Less room for insulation: risky in high-voltage machines.
Loading increasedMain drawbacks
BavB_{av}Iron loss, teeth saturation, more field copper
acacCopper loss, heating, armature reaction, commutation