- 2074 Asoj · 4 marks
Current meter use by flow characteristics
Short answer
Measurement depth dictates method: one-point at 0.6d for shallow, two-point at 0.2 and 0.8d for moderate, three or five-point for deep. Unreliable in very low/high velocity, sediment, weeds; then use floats.
Describe about the use of current meter according to flow characteristics of channel.
A current meter (cup type Price meter, or propeller type) measures velocity from the rate of rotation of its rotor: . The way it is used depends on the depth and flow condition of the channel.
According to depth (points of velocity measurement in a vertical)
| Depth | Method | Mean velocity |
|---|---|---|
| Very shallow (< 0.6 m) | One point at 0.6 d | |
| Moderate (0.6 to 3 m) | Two points at 0.2 d and 0.8 d | |
| Moderate to deep | Three points at 0.2, 0.6, 0.8 d | |
| Deep and variable | Five points (surface, 0.2, 0.6, 0.8 d, bed) |
According to flow characteristics
- Shallow, small streams: the engineer wades with a rod-mounted meter (pigmy or Price AA) held at 0.6 d.
- Wide and deep rivers: the meter is suspended from a bridge, cableway or boat with a weight (sounding weight) on a cable; the weight is chosen to keep the cable nearly vertical.
- Very low velocity (< 0.15 m/s) or very high turbulent flood: a current meter is unreliable, so floats or other methods are used.
- Sediment-laden or weedy flow: weeds and silt can foul the rotor, so it is cleaned and checked before each use.
- Uniform flow: velocity is measured at 20 to 30 verticals spaced so that no strip carries more than 5 to 10 % of the discharge.
- Time of observation: at least 40 to 60 s at each point, repeated when the velocity fluctuates.
- The meter must be rated (calibrated) in a towing tank to give , and held pointing into the flow, away from the observer's body.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Stream flow from current meter data · Engineering Hydrology, chapter 4 · asked 2×
- Stream flow from current meter, V=0.045+0.76N · Engineering Hydrology, chapter 4 · asked 2×
- Current meter discharge, rating equation · Engineering Hydrology, chapter 4
- Mid-section method discharge from current meter data · Engineering Hydrology, chapter 4
- Discharge from multi-point current meter data · Engineering Hydrology, chapter 4
- River discharge from two-point current meter data · Engineering Hydrology, chapter 4
- Stream discharge from current meter revolutions (V = 0.51N + 0.03) · Hydro Power, chapter 2 · asked 2×
- Stream discharge from current meter revolutions (v = 0.55N + 0.04) · Hydro Power, chapter 2 · asked 2×
- Gauging site selection and current meter use · Hydro Power, chapter 2
- Speech characteristics; formant and channel vocoder · Wireless Communication, chapter 6