Skip to main content

Clark IUH, 128 km2 basin

Short answer

Time-area inflows are computed as I=2.78Aᵳ/Δ t and routed through a linear reservoir with C0=0.0968, C2=0.8065. Peak IUH ordinate is 13.70 m³/s per cm at 21 h.

A basin having 128 km2^2 of drainage area has 22 hours and 14 hours of concentration time and storage constant respectively. Determine the IUH for this basin if the inter-isochrones area distribution is as below:

Travel time (hr)0-33-66-99-1212-1515-1818-2121-2424-27
Area (km2^2)27172531231463

Data and method

Area of basin A=128 km2A = 128\ \text{km}^2 (sum of the inter-isochrone areas), K=14K = 14 h, Δt=3\Delta t = 3 h. The table has 9 strips of 3 h (27 h), and all are used although tct_c is stated as 22 h.

Step 1: Translation (time-area) inflow. For 1 cm of excess rain over each strip, the inflow to the imaginary linear reservoir is

I=2.78 AiΔt m3/s per cmI = \frac{2.78\,A_i}{\Delta t}\ \text{m}^3/\text{s per cm}

Step 2: Storage (linear reservoir) routing. With S=KQS = KQ and the continuity equation, the outflow is

O2=C0(I1+I2)+C2O1,C0=Δt2K+Δt,C2=2K−Δt2K+ΔtO_2 = C_0 (I_1 + I_2) + C_2 O_1,\qquad C_0 = \frac{\Delta t}{2K+\Delta t},\quad C_2 = \frac{2K-\Delta t}{2K+\Delta t} C0=32(14)+3=0.0968C2=2(14)−32(14)+3=0.8065\begin{aligned} C_0 &= \frac{3}{2(14)+3} = 0.0968\\ C_2 &= \frac{2(14)-3}{2(14)+3} = 0.8065\end{aligned}

Check: C0+C0+C2=1.0000C_0 + C_0 + C_2 = 1.0000 (must equal 1).

Computation

Inflow ordinates are taken at the end of each strip (time =iΔt= i\Delta t); inflow at t=0t=0 and outflow at t=0t=0 are zero. Column OO is the IUH ordinate (routed outflow per cm), and the 33-h unit hydrograph ordinate is Un=(On+On−1)/2U_n = (O_n + O_{n-1})/2.

t (h)Inflow I (m³/s)IUH ordinate O (m³/s/cm)3-h UH (m³/s)
00.000.000.00
31.850.180.09
66.490.950.57
915.752.921.94
1223.176.124.52
1528.739.968.04
1821.3112.8711.42
2112.9713.7013.29
245.5612.8413.27
272.7811.1612.00
300.009.2710.22
330.007.488.37
360.006.036.75
390.004.865.45
420.003.924.39
450.003.163.54
480.002.552.86
510.002.062.30
540.001.661.86
570.001.341.50
600.001.081.21
630.000.870.97
660.000.700.79
690.000.570.63

Beyond the last row the hydrograph is a recession, with each ordinate equal to C2=0.8065C_2 = 0.8065 times the previous one (the inflow is zero after t=27t = 27 h).

Result

The IUH of the basin is given by the column OO. Peak IUH ordinate = 13.70 m³/s per cm at t = 21 h. The 3-h unit hydrograph (last column) peaks at 13.29 m³/s at t = 21 h.

✓ Answer checked by Claude Sonnet 5.5