- 2072 Kartik · 8 marks
Clark IUH, 128 km2 basin
Short answer
Time-area inflows are computed as I=2.78Aᵳ/Δ t and routed through a linear reservoir with C0=0.0968, C2=0.8065. Peak IUH ordinate is 13.70 m³/s per cm at 21 h.
A basin having 128 km of drainage area has 22 hours and 14 hours of concentration time and storage constant respectively. Determine the IUH for this basin if the inter-isochrones area distribution is as below:
| Travel time (hr) | 0-3 | 3-6 | 6-9 | 9-12 | 12-15 | 15-18 | 18-21 | 21-24 | 24-27 |
|---|---|---|---|---|---|---|---|---|---|
| Area (km) | 2 | 7 | 17 | 25 | 31 | 23 | 14 | 6 | 3 |
Data and method
Area of basin (sum of the inter-isochrone areas), h, h. The table has 9 strips of 3 h (27 h), and all are used although is stated as 22 h.
Step 1: Translation (time-area) inflow. For 1 cm of excess rain over each strip, the inflow to the imaginary linear reservoir is
Step 2: Storage (linear reservoir) routing. With and the continuity equation, the outflow is
Check: (must equal 1).
Computation
Inflow ordinates are taken at the end of each strip (time ); inflow at and outflow at are zero. Column is the IUH ordinate (routed outflow per cm), and the -h unit hydrograph ordinate is .
| t (h) | Inflow I (m³/s) | IUH ordinate O (m³/s/cm) | 3-h UH (m³/s) |
|---|---|---|---|
| 0 | 0.00 | 0.00 | 0.00 |
| 3 | 1.85 | 0.18 | 0.09 |
| 6 | 6.49 | 0.95 | 0.57 |
| 9 | 15.75 | 2.92 | 1.94 |
| 12 | 23.17 | 6.12 | 4.52 |
| 15 | 28.73 | 9.96 | 8.04 |
| 18 | 21.31 | 12.87 | 11.42 |
| 21 | 12.97 | 13.70 | 13.29 |
| 24 | 5.56 | 12.84 | 13.27 |
| 27 | 2.78 | 11.16 | 12.00 |
| 30 | 0.00 | 9.27 | 10.22 |
| 33 | 0.00 | 7.48 | 8.37 |
| 36 | 0.00 | 6.03 | 6.75 |
| 39 | 0.00 | 4.86 | 5.45 |
| 42 | 0.00 | 3.92 | 4.39 |
| 45 | 0.00 | 3.16 | 3.54 |
| 48 | 0.00 | 2.55 | 2.86 |
| 51 | 0.00 | 2.06 | 2.30 |
| 54 | 0.00 | 1.66 | 1.86 |
| 57 | 0.00 | 1.34 | 1.50 |
| 60 | 0.00 | 1.08 | 1.21 |
| 63 | 0.00 | 0.87 | 0.97 |
| 66 | 0.00 | 0.70 | 0.79 |
| 69 | 0.00 | 0.57 | 0.63 |
Beyond the last row the hydrograph is a recession, with each ordinate equal to times the previous one (the inflow is zero after h).
Result
The IUH of the basin is given by the column . Peak IUH ordinate = 13.70 m³/s per cm at t = 21 h. The 3-h unit hydrograph (last column) peaks at 13.29 m³/s at t = 21 h.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Clark IUH, 180 km2 basin · Engineering Hydrology, chapter 7 · asked 2×
- Clark IUH, 157 km2 basin · Engineering Hydrology, chapter 7
- Clark's 2-h IUH, 110 km2 · Engineering Hydrology, chapter 7 · asked 2×
- Clark IUH, 172 km2 · Engineering Hydrology, chapter 7 · asked 2×
- Clark's method flood hydrograph, 123 km2 · Engineering Hydrology, chapter 7 · asked 3×
- Clark's method flood hydrograph, 120 km2 · Engineering Hydrology, chapter 7 · asked 3×