- Asked 2/27
- 2074 Asoj · 4 marks
Clark IUH, 172 km2
Short answer
Time-area inflows from inter-isochrone areas are computed as I=2.78Aᵳ/Δ t and routed through a linear reservoir with C0=0.0476, C2=0.9048. Peak IUH ordinate is 32.87 m³/s per cm at 7 h.
A drainage basin has the following characteristics: Area = 172 km, storage constant = 10 hour, time of concentration = 8 hour. The inter-isochrone area distributions are as follows:
| Travel time (hr) | 0-1 | 1-2 | 2-3 | 3-4 | 4-5 | 5-6 | 6-7 | 7-8 |
|---|---|---|---|---|---|---|---|---|
| Inter-isochrone area (km) | 12 | 40 | 26 | 36 | 28 | 18 | 8 | 4 |
Determine the IUH for this catchment.
Data and method
Area of basin (sum of the inter-isochrone areas), h, h. The strips add up to 172 km², equal to the given area.
Step 1: Translation (time-area) inflow. For 1 cm of excess rain over each strip, the inflow to the imaginary linear reservoir is
Step 2: Storage (linear reservoir) routing. With and the continuity equation, the outflow is
Check: (must equal 1).
Computation
Inflow ordinates are taken at the end of each strip (time ); inflow at and outflow at are zero. Column is the IUH ordinate (routed outflow per cm), and the -h unit hydrograph ordinate is .
| t (h) | Inflow I (m³/s) | IUH ordinate O (m³/s/cm) | 1-h UH (m³/s) |
|---|---|---|---|
| 0 | 0.00 | 0.00 | 0.00 |
| 1 | 33.36 | 1.59 | 0.79 |
| 2 | 111.20 | 8.32 | 4.95 |
| 3 | 72.28 | 16.27 | 12.29 |
| 4 | 100.08 | 22.92 | 19.59 |
| 5 | 77.84 | 29.21 | 26.07 |
| 6 | 50.04 | 32.52 | 30.87 |
| 7 | 22.24 | 32.87 | 32.69 |
| 8 | 11.12 | 31.32 | 32.09 |
| 9 | 0.00 | 28.87 | 30.10 |
| 10 | 0.00 | 26.12 | 27.50 |
| 11 | 0.00 | 23.63 | 24.88 |
| 12 | 0.00 | 21.38 | 22.51 |
| 13 | 0.00 | 19.35 | 20.36 |
| 14 | 0.00 | 17.50 | 18.42 |
| 15 | 0.00 | 15.84 | 16.67 |
| 16 | 0.00 | 14.33 | 15.08 |
| 17 | 0.00 | 12.96 | 13.65 |
| 18 | 0.00 | 11.73 | 12.35 |
| 19 | 0.00 | 10.61 | 11.17 |
| 20 | 0.00 | 9.60 | 10.11 |
| 21 | 0.00 | 8.69 | 9.14 |
| 22 | 0.00 | 7.86 | 8.27 |
| 23 | 0.00 | 7.11 | 7.49 |
| 24 | 0.00 | 6.43 | 6.77 |
| 25 | 0.00 | 5.82 | 6.13 |
| 26 | 0.00 | 5.27 | 5.54 |
| 27 | 0.00 | 4.77 | 5.02 |
| 28 | 0.00 | 4.31 | 4.54 |
| 29 | 0.00 | 3.90 | 4.11 |
| 30 | 0.00 | 3.53 | 3.71 |
| 31 | 0.00 | 3.19 | 3.36 |
| 32 | 0.00 | 2.89 | 3.04 |
| 33 | 0.00 | 2.61 | 2.75 |
| 34 | 0.00 | 2.36 | 2.49 |
| 35 | 0.00 | 2.14 | 2.25 |
| 36 | 0.00 | 1.94 | 2.04 |
| 37 | 0.00 | 1.75 | 1.84 |
| 38 | 0.00 | 1.58 | 1.67 |
Beyond the last row the hydrograph is a recession, with each ordinate equal to times the previous one (the inflow is zero after h).
Result
The IUH of the catchment is given by the column . Peak IUH ordinate = 32.87 m³/s per cm at t = 7 h. The 1-h unit hydrograph (last column) peaks at 32.69 m³/s at t = 7 h.
✓ Answer checked by Claude Sonnet 5.5
Related questions
- Clark's 2-h IUH, 110 km2 · Engineering Hydrology, chapter 7 · asked 2×
- Clark IUH, 180 km2 basin · Engineering Hydrology, chapter 7 · asked 2×
- Clark IUH, 128 km2 basin · Engineering Hydrology, chapter 7
- Clark IUH, 157 km2 basin · Engineering Hydrology, chapter 7
- Clark's method flood hydrograph, 123 km2 · Engineering Hydrology, chapter 7 · asked 3×
- Clark's method flood hydrograph, 120 km2 · Engineering Hydrology, chapter 7 · asked 3×
- Clark's method flood hydrograph, 157 km2, K=8 h · Engineering Hydrology, chapter 7
- Heating constant and 1-hour rating (40 kVA) · Electric Machine Design, chapter 2 · asked 2×
- Surge impedance and travel time of 400 km line · High Voltage Engineering, chapter 3