Skip to main content

Clark IUH, 157 km2 basin

Short answer

For each strip compute time–area inflow Iᵢ = 2.78 Aᵢ/Δt (m³/s per cm). Route through linear reservoir with K=9.5 h, Δt=1 h, C₀=0.05, C₂=0.9. Peak IUH ordinate is 33.86 m³/s per cm at t=6 h.

A drainage basin has area = 157 km2^2, storage constant K = 9.5 h and time of concentration = 7 h. The following isochrones area distribution data are available. Determine the IUH of this catchment.

Time (h)0-11-22-33-44-55-66-7
Inter-isochrone area (km2^2)1038204532102

Data and method

Area of basin A=157 km2A = 157\ \text{km}^2 (sum of the inter-isochrone areas), K=9.5K = 9.5 h, Δt=1\Delta t = 1 h. The strips add up to 157 km², equal to the given area.

Step 1: Translation (time-area) inflow. For 1 cm of excess rain over each strip, the inflow to the imaginary linear reservoir is

I=2.78 AiΔt m3/s per cmI = \frac{2.78\,A_i}{\Delta t}\ \text{m}^3/\text{s per cm}

Step 2: Storage (linear reservoir) routing. With S=KQS = KQ and the continuity equation, the outflow is

O2=C0(I1+I2)+C2O1,C0=Δt2K+Δt,C2=2K−Δt2K+ΔtO_2 = C_0 (I_1 + I_2) + C_2 O_1,\qquad C_0 = \frac{\Delta t}{2K+\Delta t},\quad C_2 = \frac{2K-\Delta t}{2K+\Delta t} C0=12(9.5)+1=0.0500C2=2(9.5)−12(9.5)+1=0.9000\begin{aligned} C_0 &= \frac{1}{2(9.5)+1} = 0.0500\\ C_2 &= \frac{2(9.5)-1}{2(9.5)+1} = 0.9000\end{aligned}

Check: C0+C0+C2=1.0000C_0 + C_0 + C_2 = 1.0000 (must equal 1).

Computation

Inflow ordinates are taken at the end of each strip (time =iΔt= i\Delta t); inflow at t=0t=0 and outflow at t=0t=0 are zero. Column OO is the IUH ordinate (routed outflow per cm), and the 11-h unit hydrograph ordinate is Un=(On+On−1)/2U_n = (O_n + O_{n-1})/2.

t (h)Inflow I (m³/s)IUH ordinate O (m³/s/cm)1-h UH (m³/s)
00.000.000.00
127.801.390.69
2105.647.924.66
355.6015.1911.56
4125.1022.7118.95
588.9631.1426.92
627.8033.8632.50
75.5632.1533.01
80.0029.2130.68
90.0026.2927.75
100.0023.6624.97
110.0021.2922.48
120.0019.1620.23
130.0017.2518.21
140.0015.5216.39
150.0013.9714.75
160.0012.5713.27
170.0011.3211.95
180.0010.1810.75
190.009.179.68
200.008.258.71
210.007.427.84
220.006.687.05
230.006.016.35
240.005.415.71
250.004.875.14
260.004.384.63
270.003.954.16
280.003.553.75
290.003.203.37
300.002.883.04
310.002.592.73
320.002.332.46
330.002.102.21
340.001.891.99
350.001.701.79
360.001.531.61

Beyond the last row the hydrograph is a recession, with each ordinate equal to C2=0.9000C_2 = 0.9000 times the previous one (the inflow is zero after t=7t = 7 h).

Result

The IUH of the catchment is given by the column OO. Peak IUH ordinate = 33.86 m³/s per cm at t = 6 h. The 1-h unit hydrograph (last column) peaks at 33.01 m³/s at t = 7 h.

✓ Answer checked by Claude Sonnet 5.5

All Engineering Hydrology chapter 7 questions →