Failure mechanisms of bolted connection
Short answer
Bolted connections fail by bolt shear, bearing, tension, plate shear-out, net section rupture, gross yielding, block shear, or prying. For eccentric load in-plane, bolts resist direct shear plus torsional shear; resultant checked against bolt shear strength. For load out-of-plane, bolts resist direct shear plus tension, checked with (V/V_db)^2 + (T/T_db)^2 ≤ 1.0.
Explain different failure mechanisms of bolted connection. Also discuss about combination of stresses developed in different type of eccentrically loaded bolted connection.
Failure mechanisms of a bolted connection
- Shear failure of bolt: the bolt shears across one plane (single shear) or two planes (double shear). Strength .
- Bearing failure of bolt/plate: the plate elongates or tears in front of the bolt. . Prevented by adequate end and pitch distances.
- Tension failure of bolt: the bolt breaks in the threaded part under direct tension, with .
- Tearing of plate at the edge (shear-out): if the end distance is too small, the plate shears out behind the bolt.
- Tension (net-section) rupture of plate: the plate fails across the net section through the bolt holes, .
- Yielding of gross section of the plate: .
- Block shear failure: a block of plate tears out along shear and tension planes at the bolt group.
- Bolt bending (long grip): prevented by limiting the grip to (with reduced shear strength when the grip exceeds ).
- Prying failure: extra tension in bolts due to flexible connected plates.
- Slip in HSFG joints when the friction is exceeded.
Combined stresses in eccentric connections
- Load in the plane of the bolt group (eccentricity in the plane): bolts get direct shear plus shear due to torsion ; the vector sum of both is the resultant shear on the critical bolt, , checked against .
- Load perpendicular to the plane of the bolt group (bracket on column flange): bolts get direct shear and tension due to moment . Combined check for bearing-type bolts (IS 800:2007 cl. 10.3.6):
For HSFG (friction-type) bolts (cl. 10.4.6) the interaction is .
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Bolted bracket connection, 200 kN at 250 mm · Design of Steel and Timber Structure, chapter 4
- Eccentric bolted bracket, ISMB 300, 220 kN · Design of Steel and Timber Structure, chapter 4
- Tee bracket bolted to column flange, M24 · Design of Steel and Timber Structure, chapter 4
- Principal stresses; Mohr circle at failure · Soil Mechanics, chapter 10
- Thick cylinder stresses and failure criteria · Mechanics of Solids, chapter 8
- Solar PV versus hydro and their combination · Power Plant Design, chapter 1
- Behaviour and detailing of bolted and nailed joints · Design of Timber and Masonry Structures, chapter 2
All Design of Steel and Timber Structure chapter 4 questions →