- 2079 Chaitra · 8 marks
UDL capacity of MB 300 with flange plates
Short answer
Plastic design per IS 800:2007. Shear capacity of the ISMB 300 web governs; moment capacity under high shear is adequate. The factored uniformly distributed load capacity is 173 kN/m (including self-weight).
Determine uniformly distributed load carrying capacity of a laterally restrained built-up beam having MB 300 and two plates 200 mm×12 mm. Effective length of beam is 3.5 m.
Approach. Plastic design strength of the built-up section (IS 800:2007 cl. 8.2.1), then reduction of moment capacity under high shear (cl. 9.2), and the load found from the governing check. N/mm², . The beam is laterally restrained, so lateral-torsional buckling is ignored. Plates are assumed fully connected to the flanges (continuous welds or adequate bolts), one 200×12 plate on each flange. Effective span m.
Section properties
ISMB 300 (IS 808): mm, mm, mm, mm, cm⁴, mass 46.0 kg/m. Plastic modulus of ISMB 300 from its dimensions: cm³.
Classification: plate outstand from the web face mm, (plastic); ISMB web . So .
Moment capacity
kN·m. Load limited by moment: kN/m.
Shear capacity
Shear is resisted by the web of the rolled section: mm² (plates ignored, conservative).
Load limited by shear: kN/m. Shear governs (173.2 < 210.7).
Moment capacity under high shear (cl. 9.2.2)
At kN/m: kN , so the moment capacity is reduced. is the plastic strength of the section without the shear area: cm³, kN·m.
Moment at this load kN·m kN·m. OK.
Result
Self-weight kN/m.
Answer: the safe factored uniformly distributed load is kN/m (including self-weight; governed by shear), i.e. a service load of kN/m, or about 172 kN/m factored superimposed load after deducting the factored self-weight of 1.23 kN/m. Total factored reaction kN.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Beam with flange plates, 30 kN/m + 16 kN · Design of Steel and Timber Structure, chapter 7
- Built-up beam, unsupported 4 m, 40 kN/m + 100 kN · Design of Steel and Timber Structure, chapter 7
- Safe UDL on ISLB 600 beam, restrained vs unrestrained · Design of Steel and Timber Structure, chapter 7
- Built-up column, two channels toe-to-toe, 1500 kN · Design of Steel and Timber Structure, chapter 6
- Main beam of 12 m x 12 m floor · Design of Steel and Timber Structure, chapter 7
- Built-up column with battens, 4 m, 1000 kN · Design of Steel and Timber Structure, chapter 6 · asked 2×
- Bent-up bars shear, 550 mm effective depth · Design of RCC Structure, chapter 5 · asked 3×
- WSM udl capacity of 25x60 cm beam · Design of RCC Structure, chapter 2
- Bent-up bars, 600 mm effective depth · Design of RCC Structure, chapter 5 · asked 2×
- Ultimate moment of T-beam (2250 mm flange) · Design of RCC Structure, chapter 4
All Design of Steel and Timber Structure chapter 7 questions →