- 2078 Bhadra · 8 marks
WSM udl capacity of 25x60 cm beam
Short answer
With d=550 mm and Ast=1256.6 mm2, actual neutral axis is 212.63 mm, greater than balanced 158.73 mm, so over-reinforced. Moment of resistance is 89.14 kN·m. Safe total UDL is 19.16 kN/m including self weight, giving 15.41 kN/m superimposed load.
An R.C.C beam 25 cm wide and 60 cm deep has 4 bars of 20 mm dia. as tension reinforcement. The centre of bars being 5 cm above the bottom of the beam. Determine the uniformly distributed load the beam can carry over a simply supported effective span of 6.10 m. The permissible stresses in concrete and steel are taken as 7 MPa and 230 MPa respectively. Use modular ratio.
Given: mm, mm, mm, 4-20 mm dia, mm, span m, , N/mm, (modular ratio for M20).
Step 1: Constants (, N/mm, )
Step 2: Actual neutral axis (taking moments of areas about the neutral axis, transformed section)
Since mm, the section is over-reinforced: concrete reaches N/mm first, so concrete governs.
Step 3: Moment of resistance
Stress in steel at this moment: N/mm 230 N/mm.
Step 4: Safe UDL on the simply supported span
Self weight kN/m, so the superimposed load is kN/m.
Answer: total safe UDL kN/m (including self weight), i.e. superimposed load kN/m.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- WSM total udl on 300x500 beam · Design of RCC Structure, chapter 2
- Bent-up bars and stirrups, 5-25 mm bars · Design of RCC Structure, chapter 5 · asked 2×
- Shear reinforcement, 300x500 beam, 370 kN · Design of RCC Structure, chapter 5
- Shear design with curtailed bars, 30x45 cm · Design of RCC Structure, chapter 5
- Bent-up bars shear, 550 mm effective depth · Design of RCC Structure, chapter 5 · asked 3×
- WSM beam safety check, 350x650 · Design of RCC Structure, chapter 2
- T-beam: bending stress 15 cm above base · Strength of Materials, chapter 7
- Settling tank 20 m long, 3.5 m deep; 0.02 and 0.01 mm · Water Supply Engineering, chapter 6 · asked 3×
- I-section: bending stress 80 mm above base · Strength of Materials, chapter 7
- Settling tank 30 m x 3 m, 0.03 mm at 25°C; 0.025 mm at 20°C · Water Supply Engineering, chapter 6 · asked 3×