- 2075 Baisakh · 20 marks
Column with battens, 1500 kN, 8 m, fixed ends
Short answer
Effective length KL = 1.2×8 = 9.6 m. Use 2 ISMB 350 side by side, gap 150 mm (class c, λe=73.9, fcd=146 N/mm², Pd=1948 kN). Battens 320×8 mm at 1333 mm c/c, each end connected with 8 M20 bolts (two lines of 4).
Design a column section subjected to axial load of 1500 KN using rolled steel 'I' sections. Height of the column is 8 m. Both ends of column are fixed and exits sway condition. Also design lateral bracing of column using battening system.
Given/assumptions: factored load kN; height 8 m; both ends fixed against rotation but the frame is free to sway → effective length factor (IS 800:2007 Table 11, recommended value), so mm. The column is built up of two rolled I-sections (ISMB) placed side by side and tied by battens (bolted, M20 4.6); E250 (, ). The battens are on the flange faces; the bolt group on each I-section is centred on its web line, so .
1. Section: 2 ISMB 350 placed side by side with a gap (webs parallel)
mm², mm⁴, mm, mm, mm, mm. Built-up members are buckling class c.
- Battened column: (cl. 7.6.1.5)
- N/mm² (curve c, , ) → kN kN ✓
2. Clear gap (so that )
The centroid of each section is at from the column axis:
Provide mm. mm⁴, mm, , kN ✓
3. Spacing of battens (cl. 7.7.1.4)
The slenderness of one section between battens must be :
For the length of 8000 mm provide 6 bays, i.e. 7 battens at mm c/c.
4. Size of battens (cl. 7.7.2)
- Distance between the connection lines mm
- End battens: depth → 320 mm; intermediate battens: depth mm → 320 mm
- Thickness → 8 mm; length of batten mm (to take the two bolt lines on each flange).
5. Design forces on a batten
Transverse shear kN, number of batten planes :
- Plate in bending: mm³ (intermediate batten); N/mm² N/mm² ✓ ( kN·m)
- Shear: N/mm² N/mm² ✓
6. Bolts connecting battens to the sections (M20, 4.6)
A bolt cannot be placed on the web line of an I-section, so at each end use 8 bolts in two vertical lines of 4, one line on each side of the web (35 mm from the web centre line, pitch 80 mm, end 40 mm). kN, bearing on 8 mm kN → bolt value kN.
- mm²
- Direct shear per bolt kN (along the column); moment on the extreme bolt (35, 120): kN across and kN along the column
- Resultant kN kN ✓
Answer: 2 ISMB 350 placed side by side with a gap (webs parallel), clear gap 150 mm; battens 320 × 8 mm (end and intermediate), 430 mm long, at 1333 mm c/c, with 8 M20 bolts (two lines of 4) at each end.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Built-up column, battens, 6 m unsupported, 1200 kN · Design of Steel and Timber Structure, chapter 6
- Built-up column with battens, 10 m, 1080 kN · Design of Steel and Timber Structure, chapter 6 · asked 4×
- Built-up column with battens, 4 m, 1000 kN · Design of Steel and Timber Structure, chapter 6 · asked 2×
- Built-up column with battens, 6 m, 1200 kN · Design of Steel and Timber Structure, chapter 6
- Built-up column, two channels toe-to-toe, 1500 kN · Design of Steel and Timber Structure, chapter 6
- Braced built-up column, 3 m, 1600 kN · Design of Steel and Timber Structure, chapter 6 · asked 2×
- Brick column design for 80 kN axial load · Concrete Technology and Masonry Structure, chapter 8
- Bar fixed at both ends: load shares, displacements · Strength of Materials, chapter 3
- Fixed-end column 4 m, 1000 kN · Design of RCC Structure, chapter 10
- Euler's formula both ends fixed, with limitations · Strength of Materials, chapter 8
All Design of Steel and Timber Structure chapter 6 questions →