Moment capacity of unrestrained ISMB 500
Short answer
Elastic critical moment M_cr = 278.7 kN·m; non-dimensional slenderness λ_LT = 1.355; reduction factor χ_LT = 0.440; design bending strength f_bd = 100.1 N/mm². Moment capacity M_d = 205 kN·m.
Calculate the moment carrying capacity of laterally unrestrained beam made of ISMB500 and length of member is equal to 6m. Assume necessary data suitably.
Approach. Moment capacity of a laterally unrestrained beam, IS 800:2007 cl. 8.2.2: , , with from Annex E.
Assumed data
- ISMB 500 @ 86.9 kg/m (IS 808): , , , mm, cm⁴, cm³.
- Fe 410: N/mm². Simply supported over 6 m, ends restrained against torsion with the flanges free to warp, so mm (Table 15). No intermediate lateral restraint. Load applied at the shear centre level (normal loading, the usual assumption).
Step 1: Section properties
Plastic modulus cm³ (plastic section, ; , ).
Step 2: Elastic critical moment
(, N/mm²).
Step 3: Reduction factor
Rolled section: .
Step 4: Moment capacity
(limit kN·m, not governing).
Answer: moment carrying capacity kN·m, about 44% of the fully restrained value kN·m. For a UDL this corresponds to a factored load kN/m including self-weight.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Effect of lateral restraint on moment capacity · Design of Steel and Timber Structure, chapter 7
- Safe UDL on ISLB 600 beam, restrained vs unrestrained · Design of Steel and Timber Structure, chapter 7
- Laterally supported I-section for 700 kNm · Design of Steel and Timber Structure, chapter 7
- UDL capacity of MB 300 with flange plates · Design of Steel and Timber Structure, chapter 7
- Slab base for ISMB 350, 850 kN service · Design of Steel and Timber Structure, chapter 6
- Beam with slab, 20 kN/m, 350 mm wall · Design of Steel and Timber Structure, chapter 7
- Define plastic moment capacity of beam · Strength of Materials, chapter 7
- Fusing current and current carrying capacity · Switchgear and Protection, chapter 3
- Current carrying capacity of cable · Industrial Power Distribution and Illumination, chapter 3
- When HVDC is economical; equal transmission capacity · Power Electronics, chapter 7
All Design of Steel and Timber Structure chapter 7 questions →