- 2068 Bhadra (old course) · 14 marks
Check eccentric fillet weld, 8 mm, P=100 kN
Short answer
The weld experiences direct shear and bending moment, giving resultant stress 155.9 MPa. This exceeds the permissible shear stress of 108 MPa. Hence the joint is not safe.
For the electric (eccentric) connection as shown, determine whether the joint is safe or not. Size of the fillet weld is 8mm and load P is equal to 100KN. Assume that permissible shear stress in the weld is 108 MPa. [Figure: 14 mm thick gusset plate welded to a column flange with 20 cm weld width at top and bottom and 20 cm depth; P = 100 kN acts at 40 cm from the weld face; 20 cm dimension marked]
Basis: working stress method (permissible shear stress in weld 108 N/mm²). The gusset (14 mm) is welded to the column flange by a C-shaped fillet weld: top and bottom 200 mm and vertical 200 mm. kN acts parallel to the flange at mm from the weld plane, giving direct shear and bending. Weld size mm, throat mm.
Weld group (per mm of throat)
- mm
- mm³
- N·mm
Force per mm of weld at the extreme weld (y = 100 mm)
- Shear: N/mm
- Bending: N/mm
- Resultant N/mm
Stress in the weld
Answer: the joint is NOT safe (stress is about 156 N/mm² against 108 N/mm² permissible). It needs a larger weld (about 12 mm) or a deeper weld.
✓ Answer checked by Claude Opus 5.5 (high effort)
Related questions
- Fillet weld size for bracket plate, 100 kN · Design of Steel and Timber Structure, chapter 4
- Shop welded bracket, 5 mm fillet, safe load · Design of Steel and Timber Structure, chapter 4
- Weld length for ISA 90x90x12, 100 kN · Design of Steel and Timber Structure, chapter 5
- Weld size for bracket on ISMB 400 · Design of Steel and Timber Structure, chapter 4
- Bolted bracket connection, 200 kN at 250 mm · Design of Steel and Timber Structure, chapter 4
- Weld length for ISA 100x100x8, 200 kN · Design of Steel and Timber Structure, chapter 5
- Footing for 1600 kN with shear check · Design of RCC Structure, chapter 11
- Brick and mortar for 230 mm wall (100 kN/m) · Concrete Technology and Masonry Structure, chapter 8 · asked 7×
- Check column 600x400 with 8-28 mm bars · Design of RCC Structure, chapter 10
- Footing with load transfer check, 1000 kN · Design of RCC Structure, chapter 11
All Design of Steel and Timber Structure chapter 4 questions →