Skip to main content

Degree of treatment, domestic + industrial

Short answer

The combined sewage BOD5 is 1636.4 mg/l. To keep river DO above 4 mg/l, the treated effluent BOD5 must be reduced to 588.35 mg/l, requiring about 64% BOD removal.

The sewage of a town is a mixture of domestic sewage and industrial sewage. The sewage is to be treated at the sewage treatment plant before discharging into river. Determine the degree of treatment required for the following data: Population = 40000; Domestic sewage = 175 lpcd; BOD of domestic sewage = 50 gm/capita/day; Flow of industrial waste = 4 × 10⁶ liters/day; BOD of industrial waste = 4000 mg/l; DO of both domestic and industrial sewage = 0; River discharge = 8500 liters/sec; BOD of river water = 0; DO of river water = 8 mg/l; k1 = 0.1/day and k2 = 0.1/day. Assume other data as required.

Step 1: Combined sewage

SourceFlow (m³/d)BOD load (kg/d)
Domestic (40000×17540000\times 175 l)70002000 (40000×0.0540000\times 0.05)
Industrial400016000
Total1100018000
Qs=1100086400=0.1273 m3/s,BOD5=18000×100011000=1636.4 mg/lQ_s=\frac{11000}{86400}=0.1273\ \text{m}^3/\text{s},\qquad BOD_5=\frac{18000\times 1000}{11000}=1636.4\ \text{mg/l}

Step 2: Assumptions

River flow Qr=8.5Q_r=8.5 m³/s, DOr=8DO_r=8 mg/l, BOD =0=0. Assumed (not given): temperature 20°C so DOsat=9.17DO_{sat}=9.17 mg/l, and the minimum DO to be kept in the river is 4 mg/l (needed for fish life). The rate constants are taken as base 10, K=R=0.1K=R=0.1/day, so f=1f=1 and the critical time is tc=Lm−D02.303 KLmt_c=\dfrac{L_m-D_0}{2.303\,K L_m} with Dc=(2.303KLmtc+D0)10−KtcD_c=(2.303K L_m t_c+D_0)10^{-Kt_c}.

Step 3: Mixing and permissible deficit

DOmix=0.1273×0+8.5×8.08.627=7.88 mg/lD0=DOsat−DOmix=9.17−7.88=1.29 mg/lDc(allowed)=DOsat−DOmin=9.17−4.0=5.17 mg/l\begin{aligned} DO_{mix} &= \frac{0.1273\times 0 + 8.5\times 8.0}{8.627} = 7.88\ \text{mg/l}\\ D_0 &= DO_{sat}-DO_{mix} = 9.17-7.88 = 1.29\ \text{mg/l}\\ D_{c(allowed)} &= DO_{sat}-DO_{min} = 9.17-4.0 = 5.17\ \text{mg/l} \end{aligned}

Step 4: Permissible BOD of the mixture

With K=0.1K=0.1 and R=0.1R=0.1 (base 10), f=R/K=1.00f=R/K=1.00. The critical deficit is

tc=Lm−D02.303 KLm (f=1),Dc=(2.303KLmtc+D0) 10−Ktct_c=\frac{L_m-D_0}{2.303\,K L_m}\ (f=1),\qquad D_c = (2.303K L_m t_c + D_0)\,10^{-Kt_c}

and DcD_c must not exceed 5.17 mg/l. Solving these two equations for LmL_m by trial (with D0=1.29D_0=1.29 fixed) gives Lm=12.70L_m=12.70 mg/l, with tc=3.902t_c=3.902 days (check: Dc=5.17D_c=5.17 mg/l).

Step 5: Permissible BOD of the effluent

Lraw=BOD51−10−5K=1636.40.6838=2393.14 mg/lLr=0.00 mg/l (river)Ls=Lm(Qs+Qr)−QrLrQs=12.70×8.627−8.5×0.000.1273=860.45 mg/l\begin{aligned} L_{raw} &= \frac{BOD_5}{1-10^{-5K}} = \frac{1636.4}{0.6838} = 2393.14\ \text{mg/l}\\ L_r &= 0.00\ \text{mg/l (river)}\\ L_s &= \frac{L_m(Q_s+Q_r)-Q_rL_r}{Q_s} = \frac{12.70\times 8.627 - 8.5\times 0.00}{0.1273} = 860.45\ \text{mg/l} \end{aligned}

So the treated effluent can have BOD5≈588.35BOD_5 \approx 588.35 mg/l.

Degree of treatment=2393.14−860.452393.14×100=64.0%\text{Degree of treatment} = \frac{2393.14-860.45}{2393.14}\times 100 = 64.0\%

Answer: the sewage BOD5 must be reduced from 1636.4 mg/l to about 588.35 mg/l, i.e. the degree of treatment required is about 64.0%. This needs a secondary biological plant (for example ASP, with the industrial waste pre-treated).

✓ Answer checked by Claude Opus 5.5 (high effort)

All Sanitary Engineering chapter 6 questions →